| 600 mm |
> 850 mm | 600 mm |
THE LOAD DOOR REVERSAL
The load door can be installed by the user in the opposite side. It can help to easily put and remove the laundry or if there is a limit to install the appliance. (see separate leaflet).
ELECTRICAL CONNECTION
•Connect the appliance to a grounded socket. Refer to the applicable electri- cal requirements.
•Make sure that the electrical data on the rating plate agrees with the power supply.
•Always use a correctly installed shock- proof socket.
•Do not use multiple plugs and exten- sion cables. There is a risk of fire.
•All replacements of power supply cable must be carried out by our Service.
•Make sure not to squash or cause dam- age to the mains plug and cable be- hind the appliance.
•Do not pull the mains cable to discon- nect the appliance. Always pull the mains plug.
•The plug must be dry.
The data about mains voltage, type of current and the necessary fuse are on the rating plate and in the “TECHNICAL IN- FORMATION” chapter. The rating plate is behind the load door (see the “PRODUCT DESCRIPTION” chapter).
The appliance has a power supply cable with plug fitted with 13 A fuse. If necessa- ry, replace the fuse in the plug by 13 A ASTA BS 1363/A approved fuse.
The wires in the power supply cable are coloured as follow:
ENGLISH 23
A
B
C |
D |
A)green and yellow - ground — earth (E)
B)brown - live (L)
C)cord clamp
D)blue - neutral (N)
The green and yellow coloured wire must be connected to the terminal with E mark
or the ground mark or the green and yellow coloured terminal.
The blue coloured wire must be connec- ted to the terminal N or black coloured . The brown coloured wire must be connec- ted to the terminal L or red coloured . The wires of the cable must be no cut or stray strands of wire present and the cable clamp must be secure over the outer sheath.
Permanent connection
The necessary condition of permanent connection is to install a
The type of switch must be correct for the necessary load and must align with appli- cable electrical requirements.
The switch must not break the yellow and green coloured ground wire.