Page 118

e. Open main door. The dryer must stop processor (computer) board must go out.

and ALL indicator lights on the back side of the micro- (Refer to illustration on previous page [page 113].)

f.Try to restart the dryer with the main door open.

g.The microprocessor (computer) board's L.E.D. display must read "DOOR."

h.Close the main door and restart the dryer.

i.Functional check of microprocessor (computer) board is complete.

2.Direct Spark Ignition (DSI) System

a.Upon completing installation of the replacement

Direct Spark Ignition (DSI) module, reestablish power to the dryer.

b. Start the drying cycle.

c. The ignition (DSI) module's L.E.D. indicator will light "red" for up to approximately 1.5 seconds (prepurge time).

d. The module's indicator light will then turn “green.” The gas valve will be energized and the ignitor probe will spark for approximately 8 seconds. The burner flame should now be established.

e.With the burner flame on, remove the flame sensor wire from the FS terminal of the DSI module.

f.The burner flame must shut off and the ignition module must lock out with the DSI module's indicator light "red."

g Stop the drying cycle, with the flame sensor wire still removed, restart the drying cycle.

h.The ignition module must proceed through the prepurge, with the indicator light "red," the ignition trial time of approximately 8 seconds, with the indicator light "green," and then proceed to lock out with the indicator light "red."

i.Functional check of the Direct Spark Ignition (DSI) Module is complete.

1)Replace the flame sensor wire from the FS terminal to the DSI module.

114

Image 118
Contents American Dryer Corporation Retain This Manual In a Safe Place For Future Reference Important Note to PurchaserFor Your Safety Page Table of Contents Section Troubleshooting AD-310 Reference Guide Base Section AD-310 Operator CONTROLS/INDICATORS AD-310 Machine Operational SummaryControl Power On END of Cycle / Heater Fault Indicator / AIR JET AD-310 Machine Operation Troubleshooting Information AIR JETUnload Tilted Load TiltedDRY If Both AIR Flow Switches are not Open AT this Time GAS PressureImportant Information ONE 1 Burner will not Ignite AT the Beginning of a Cycle System Ladder DiagramONE 1 Burner will not Ignite During a Drying Cycle Solenoid Control Optional Sprinkler Control SignalsLint Drawer / Guard Status Page Explosion could Result What to do if YOU Smell GASStandards National Electric Code ANSI/NFPA no -LATEST EditionSuggested Cleaning Schedule CleaningLiquids Monthly Lubrication Adjustments Days After Installation and Every 6 Months ThereafterGas Dimensions Obligation Page ADG-310 Gas Non-Tilt Installation Requirements Enclosure / AIR Supply / Exhaust RequirementsOperational Service Check Procedure Electrical Requirements and GAS RequirementsHeat Section Direct Spart Ignition DSI System COMPONENTS/FUNCTIONS24 VAC Direct Spark Ignition DSI Module Repairable ADC Direct Spark Ignition DSI Operation Flow Chart Troubleshooting the Direct Spark Ignition DSI System ManometerPage Page Page First Visual Check Second Visual Check Third Visual Check Are no Retries Leaks with a Flame Continuously Page Page Create a Potential Safety Hazard Page Steam Coil System Operation General OverviewPage Page Page Page Sprinkler System Description Require any adjustment Prior to November 14 As of November 14 Page Supplies Before Servicing the Dryer MAN3169 Tilting System Description Page Tilting Pistons Page Page Page Page AIR JET Assembly Page Blower Squirrel Cage Fan Motor Assembly Leave enough movement for V-belt adjustment Page Important do not Overtighten V-BELTS Important do not Overtighten V-BELTS Page Page Filter and Regulator Assembly Door Systems Page Page Page Page Allow a full 72 hours for the silicone to cure Page Control and Electrical System Page Button does not Disable the High Voltage to the Dryer If the Opposite Side is not LEVEL, the Dryer will not Tilt ºC + Page Page Page Page Page MAN3405 Page Page Page Tumbler Drive System Important do not Over Tighten Turnbuckle Install new V-belts Tighten turnbuckle Page 100 Do not tighten 102 103 104 Troubleshooting Drive motor is not operating does not start Impellor fan motor is not operating does not start 108 109 Dryer operates but is taking too long to dry Excessive noise and vibration Dryer will not tilt Procedure for Functional Check Replacement Components 114 ADC450413 05/11/99-25 01/31/00-5