Page 72

2.Blower (squirrel cage fan) and Fan Motor Component Replacement

a)Blower (squirrel cage fan) Motor Replacement

1)Discontinue electrical service to the dryer.

2)Mark and identify the wires that will be removed for proper reinstallation.

3)Loosen the bolts from the motor to the motor base ...

(a)Slide the blower (squirrel cage fan) motor forward.

(b)Remove the V-belts.

(c)Remove loosened bolts.

4)Remove the bolts from the bushing.

5)Insert bolts into the threaded holes.

6)Tighten the bolts evenly for motor pulley removal.

7)Mark the inside of the motors' shaft before removing the bushing.

8) Loosen the set screws on the bushing.

MAN3286

9)Remove the bushing.

10)Measure the mark on the shaft (from Step #7) to the end of the shaft and mark the new motors' shaft.

11)Slide the motor pulley on to the new blower (squirrel cage fan) motors' shaft.

12)Slide the bushing on to the shaft until the inside of the bushing meets the mark (from Step #11) on the new motors' shaft.

13) Tighten and secure the set screws on the bushing.

14)Insert bolts into the large holes on the bushing and thread them into the motor pulley.

15)Tighten the bolts evenly for motor pulley installation.

16)

Align the pulleys.

 

17)

Tighten (hand tight only) the bolts from the new motor to

 

 

the motor base ...

MAN3286

 

 

Leave enough movement for V-belt adjustment.

6 8

Image 72
Contents American Dryer Corporation Retain This Manual In a Safe Place For Future Reference Important Note to PurchaserFor Your Safety Page Table of Contents Section Troubleshooting AD-310 Reference Guide Base Section AD-310 Operator CONTROLS/INDICATORS AD-310 Machine Operational SummaryControl Power On END of Cycle / Heater Fault Indicator / AIR JET AD-310 Machine Operation Troubleshooting Information AIR JETUnload Tilted Load TiltedDRY If Both AIR Flow Switches are not Open AT this Time GAS PressureImportant Information System Ladder Diagram ONE 1 Burner will not Ignite AT the Beginning of a CycleONE 1 Burner will not Ignite During a Drying Cycle Optional Sprinkler Control Signals Solenoid ControlLint Drawer / Guard Status Page Explosion could Result What to do if YOU Smell GASStandards National Electric Code ANSI/NFPA no -LATEST EditionCleaning Suggested Cleaning ScheduleLiquids Monthly Lubrication Adjustments Days After Installation and Every 6 Months ThereafterGas Dimensions Obligation Page ADG-310 Gas Non-Tilt Installation Requirements Enclosure / AIR Supply / Exhaust RequirementsOperational Service Check Procedure Electrical Requirements and GAS RequirementsHeat Section Direct Spart Ignition DSI System COMPONENTS/FUNCTIONS24 VAC Direct Spark Ignition DSI Module Repairable ADC Direct Spark Ignition DSI Operation Flow Chart Troubleshooting the Direct Spark Ignition DSI System ManometerPage Page Page First Visual Check Second Visual Check Third Visual Check Are no Retries Leaks with a Flame Continuously Page Page Create a Potential Safety Hazard Page Steam Coil System Operation General OverviewPage Page Page Page Sprinkler System Description Require any adjustment Prior to November 14 As of November 14 Page Supplies Before Servicing the Dryer MAN3169 Tilting System Description Page Tilting Pistons Page Page Page Page AIR JET Assembly Page Blower Squirrel Cage Fan Motor Assembly Leave enough movement for V-belt adjustment Page Important do not Overtighten V-BELTS Important do not Overtighten V-BELTS Page Page Filter and Regulator Assembly Door Systems Page Page Page Page Allow a full 72 hours for the silicone to cure Page Control and Electrical System Page Button does not Disable the High Voltage to the Dryer If the Opposite Side is not LEVEL, the Dryer will not Tilt ºC + Page Page Page Page Page MAN3405 Page Page Page Tumbler Drive System Important do not Over Tighten Turnbuckle Install new V-belts Tighten turnbuckle Page 100 Do not tighten 102 103 104 Troubleshooting Drive motor is not operating does not start Impellor fan motor is not operating does not start 108 109 Dryer operates but is taking too long to dry Excessive noise and vibration Dryer will not tilt Procedure for Functional Check Replacement Components 114 ADC450413 05/11/99-25 01/31/00-5