SECTIONIII

INSTALLATION PROCEDURES

Installation should be performed by competent technicians in accordance with local and state codes. In the absence of these codes, the installation must conform to applicable American National Standards: ANSI Z223.1- LATEST EDITION (National Fuel Gas Code) or ANSI/NFPA NO. 70-LATEST EDITION (National Electrical Code) or in Canada, the installation must conform to applicable Canadian Standards: CAN/CGA-B149.1-M91 (Natural Gas) or CAN/CGA-B149.2-M91 (Liquid Propane [L.P.] Gas) or LATEST EDITION (for General Installation and Gas Plumbing) or Canadian Electrical Codes Parts 1 & 2 CSA C22.1-1990 or LATEST EDITION (for Electrical Connections).

A. LOCATION REQUIREMENTS

Before installing the dryer, be sure the location conforms to local codes and ordinances. In the absence of such codes or ordinances the location must conform with the National Fuel Gas CodeANSI.Z223.1 LATEST EDITION, or in Canada, the installation must conform to applicable Canadian Standards: CAN/CGA-B149.1-M91 (Natural Gas) or CAN/CGA-B149.2-M91 (L.P. Gas) or LATEST EDITION (for General Installation and Gas Plumbing).

1.The dryer must be installed on a sound level floor capable of supporting its weight. Carpeting must be removed from the floor area that the dryer is to rest on.

IMPORTANT: “The dryer must be installed on noncombustible floors only.”

2.The dryer must not be installed or stored in an area where it will be exposed to water and/or weather.

3.The dryer is for use in noncombustible locations.

4.Provisions for adequate air supply must be provided as noted in this manual (refer to Fresh Air Supply in Section D).

5.Clearance provisions must be made from combustible construction as noted in this manual (refer to Dryer Enclosure Requirements in Section C).

6.Provisions must be made for adequate clearances for servicing and for operation as noted in this manual (refer to Dryer Enclosure Requirements in Section C).

7.Dryer must be exhausted to the outdoors as noted in this manual (refer to Exhaust Requirements in Section E).

8.Dryer must be located in an area where correct exhaust venting can be achieved as noted in this manual (refer to Exhaust Requirements in Section E).

9.The dryer must be installed with a proper exhaust duct connection to the outside.

10.The dryer must be installed with provisions for adequate combustion and make-up air supply.

CAUTION: This dryer produces combustible lint and must be exhausted to the outdoors. Every 6 months, inspect the exhaust ducting and remove any lint build up.

10

Image 14
Contents ML-75DIII Retain This Manual In a Safe Place For Future Reference For Your Safety Page Table of Contents Section Procedure for Functional Check of Replacement Important Information Receiving and HandlingSafety Precautions What to do if YOU Smell GASStandards SPECIFICATIONS/COMPONENT Identification SpecificationsSpecifications Component Identification Dryer Rear View Illus. No Installation Procedures Location RequirementsUNPACKING/SETTING UP Dryer Enclosure Requirements Fresh AIR Supply Exhaust Requirements General Exhaust Ductwork InformationPage Page Page Page Electrical Information Electrical RequirementsMLS-75 Steam MLE-75 Electric Grounding Single-Phase 1Ø Electrical Connections Leads Page Phase 3ø Wiring Connections/Hookup Reversing Models Only Electrically Heated Models Only GAS Information Type of GAS Page Steam Information Operating Steam Pressure Steam Damper Air System Connections Compressed AIR Supply AIR Pressure Page Preparation for OPERATION/START-UP Preoperational Tests Basket Coating Preoperational Instructions Shut Down Instructions Parts SERVICE/PARTS InformationService Warranty Warranty InformationReturning Warranty Cards Returning Warranty PartsPage Routine Maintenance CleaningAdjustments DaysLubrication Procedure for Functional Check Replacement Components Page Reversing Timer SPIN/DWELLADJUSTMENTS SectionviiiData Label Information Data LabelSerial Number For Phase 7 Models P O R T a N TFor Dual Timer Models S. In Action Fire Suppression System F.S.SInstallation Before YOU Start Check Local Codes and PermitsWater Connections Optional Manual Bypass Fire Suppression System F.S.S. Theory of Operation Parts Break Down Comp x 3/8 M.P.T. Brass Connector 822752 ADC113343 1 09/26/01-25

ML-75DIII specifications

The American Dryer Corp ML-75DIII is a high-performance dryer designed to meet the demanding needs of commercial laundry facilities. Known for its robust construction and innovative features, this dryer sets a new standard for efficiency and reliability in laundry applications.The ML-75DIII boasts an impressive drying capacity, making it an ideal choice for laundromats, hotels, and other establishments with high laundry volumes. Its 75-pound capacity allows for large loads, reducing the time and energy required to dry multiple smaller batches. This efficiency not only saves time but also optimizes operational workflow, enabling staff to focus on other critical tasks.

One of the standout features of the ML-75DIII is its advanced control system. Equipped with an intuitive microprocessor control, it allows users to select from multiple drying cycles, temperatures, and times, ensuring that every batch is processed to perfection. The control panel is user-friendly, making it easy for operators to make adjustments and monitor the drying process in real-time.

Moreover, the ML-75DIII incorporates intelligent moisture sensing technology that detects the moisture level of the laundry and adjusts the drying time accordingly. This feature prevents over-drying, preserving the quality of fabrics while reducing energy consumption. The dryer’s high-efficiency heating elements further contribute to its performance, delivering powerful heat while minimizing energy use.

Safety is also a top priority in the design of the ML-75DIII. The dryer is equipped with a host of safety features, including a door safety switch that prevents operation when the door is open. Additionally, the machine includes a robust lint filtration system that ensures lint is effectively captured, reducing fire hazards and promoting a clean working environment.

Durability is another hallmark of the ML-75DIII. Its heavy-duty construction using high-quality materials ensures that the dryer can withstand the rigors of daily use in a commercial setting. The stainless steel drum is resistant to corrosion and wear, providing a long-lasting solution for any laundry operation.

In conclusion, the American Dryer Corp ML-75DIII combines advanced technology with practical features to deliver a top-tier drying experience. Its high capacity, intelligent controls, energy efficiency, and safety measures make it a preferred choice for commercial laundry facilities looking to enhance productivity and reliability.