3.Piping/Connections

ALL components/materials must conform to National Fuel Gas Code Specifications ANSI Z223.1-LATEST EDITION, or in Canada, CAN/CGA-B149.1-M91 (Natural Gas) or CAN/CGA-B149.2-M91 (Liquid Propane [L.P.] Gas) or LATEST EDITION (for General Installation and Gas Plumbing), as well as local codes and ordinances and must be done by a qualified professional. It is important that gas pressure regulators meet applicable pressure requirements, and that gas meters be rated for the total amount of ALL the appliance BTUs being supplied.

The dryer is provided with a 1” N.P.T. inlet pipe connection extending out the back area of the burner box. The minimum pipe size connection (supply line) to the dryer is 1” N.P.T. For ease of servicing, the gas supply line of each dryer must have its own shutoff valve.

The size of the main gas supply line (header) will vary depending on the distance this line travels from the gas meter or, in the case of L.P. gas, the supply tank, other gas-operated appliances on the same supply line, etc. Specific information regarding supply line size should be determined by the gas supplier.

NOTE: Undersized gas supply piping can create a low or inconsistent pressure, which will result in erratic operation of the burner ignition system.

Consistent gas pressure is essential at ALL gas connections. It is recommended that a 1” (2.54 cm) pipe gas loop be installed in the supply line servicing a bank of dryers. An in-line pressure regulator must be installed in the gas supply line (header) if the (natural) gas pressure exceeds 12.0 inches (29.9 mb) of water column pressure (W.C.).

IMPORTANT: A water column pressure of 3.5 inches (8.7 mb) for natural gas and 10.5 inches (26.1 mb) for L.P. dryers is required at the gas valve pressure tap of each dryer for proper and safe operation.

A 1/8” N.P.T. plugged tap, accessible for a test gauge connection, must be installed in the main gas supply line immediately upstream of each dryer.

IMPORTANT: Pipe joint compounds that resist the action of natural and L.P. gases must be used.

IMPORTANT: Test ALL connections for leaks by brushing on a soapy water solution (liquid detergent works well).

WARNING: NEVER TEST FOR LEAKS WITH A FLAME!!!

ALL components/materials must conform to National Fuel Gas Code Specifications ANSI Z223.1-LATEST EDITION, or in Canada, CAN/CGA-B149.1-M91 (Natural Gas) or CAN/CGA-B149.2-M91 (L.P. Gas) or LATEST EDITION (for General Installation and Gas Plumbing), as well as local codes and ordinances and must be done by a qualified professional. It is important that gas pressure regulators meet applicable pressure requirements, and that gas meters be rated for the total amount of ALL the appliance BTUs being supplied.

29

Image 33
Contents AD-120ES Retain This Manual In a Safe Place For Future Reference For Your Safety Page Table of Contents Section Procedure for Functional Check of Replacement Receiving and Handling Important InformationWhat to do if YOU Smell GAS Safety PrecautionsStandards Specifications SPECIFICATIONS/COMPONENT IdentificationADG-120ES ADE-120ES ADS-120ES Component Identification Page Location Requirements Installation ProceduresUNPACKING/SETTING UP Page This Exhaust Duct Transition Piece Must be Installed First Dryer Enclosure Requirements Fresh AIR Supply Requirements General Exhaust Ductwork Information Exhaust RequirementsPage Page Page Page Page Electrical Requirements Electrical InformationElectrical Service Specifications PER Dryer ADE-120 III 72 kW Electric Reversing, 3ø Page Page GAS Information Type of GAS Page Page Steam Information 689.47 kPa204 kg/hr Page COM Pressed AIR Pressure AIR Supply Page Preparation for Operation Preoperational Tests Page Basket Tumbler Coating Shutdown InstructionsOperating Instructions SERVICE/PARTS Information ServiceParts Returning Warranty Cards Warranty InformationWarranty Returning Warranty PartsPage Routine Maintenance CleaningSuggested Cleaning Schedule Steam Dryers Lubrication AdjustmentsDrive motor is not operating does not start TroubleshootingBlower motor is not operating does not start Microprocessor controller computer display reads door Microprocessor controller computer display reads dSFLPage No heat for Electric Models only No heat for Steam Models onlyCondensation on main door glass Dryer operates but is taking too long to dryExcessive noise and/or vibration Dryer is making scraping noise at basket tumbler areaGAS Models Drive motor only is not operating does not startElectric Models Dryer operates but is taking too long to dry load Condensation on main door glass Data Label Data Label InformationHeat Input for GAS Dryers Data Label Model NumberTiming Legend Reversing Timer SPIN/DWELLADJUSTMENTSProcedure for Functional Check Replacement Components Page P O R T a N T ADC P/N114501

AD-120ES III specifications

The American Dryer Corp AD-120ES III is a high-performance, energy-efficient hand dryer designed for commercial environments where durability and hygiene are key requirements. This model combines advanced technology with user-friendly features to deliver a superior drying experience.

One of the standout features of the AD-120ES III is its powerful 1.1 horsepower motor, which allows the dryer to deliver a high-speed airflow of approximately 200 miles per hour. This rapid drying capability significantly reduces drying time, ensuring that users have a quick and effective way to dry their hands. Additionally, the dryer operates quietly, making it suitable for environments where noise control is important, such as offices, restaurants, and educational institutions.

Energy efficiency is another hallmark of the AD-120ES III. The unit is equipped with an energy-saving mode that can reduce power consumption by up to 85%. This feature not only helps to conserve energy but also contributes to lower operating costs, making it an eco-friendly choice for businesses. The dryer’s electronic sensor technology ensures that it activates only when hands are underneath, further enhancing its efficiency.

The design of the AD-120ES III emphasizes hygiene and cleanliness. With a touchless operation, users can dry their hands without needing to touch any surface, reducing the risk of cross-contamination. The dryer also features a high-quality HEPA filtration system that captures 99.97% of particles as small as 0.3 microns from the air that passes through it, ensuring that the air used for drying is clean and safe.

Durability and ease of maintenance are also key characteristics of the AD-120ES III. Constructed from robust stainless steel, this hand dryer is designed to withstand the rigors of high-traffic environments. Its easy-to-remove cover allows for straightforward maintenance, making it simple to keep the unit in optimal working condition.

In summary, the American Dryer Corp AD-120ES III is a reliable and effective choice for commercial hand drying solutions. With its powerful motor, energy-saving features, touchless operation, and high-quality filtration, it meets the needs of both users and facility managers looking for efficiency, hygiene, and reliability. The combination of advanced technology and thoughtful design makes the AD-120ES III a leading option in the hand dryer market.