Sterling SFC-K 40, SFC-K 50 operating instructions Compressed air supply

Page 13

SFC-K

2.3. Compressed air supply

For operation of the valve, a com- pressed-air supply (1/4“) is needed.

Check compressed air piping for correct installation and assembly.

Check fittings, length and quality of the hose connections for agree- ment with requirements.

The operating pressure is 5-6 bar

(72 - 87 PSI) (system overpressure).

Check the compressed air supplied by the plant’s supply network.

Adjust compressed air pressure to

5-6 bar (72-87 PSI) (system overpressure).

Compressed air must be dewatered and oiled.

Maintenance unit

Install a maintenance unit (pressure reducer with water separator and oiler) if re- quired.

Connect the unit to the plant’s supply network by means of a hose.

L

F

SM3-635b

Depressurize compressed air supply lines which must be opened.

Compressed air must be dewatered and oiled.

Adjust pressure to a max. value of 6 bar (87 PSI) (system overpressure).

Installation instructions 12

Image 13
Contents Sterling Material Processing Operating Instructions Safety Filters SFC-KSFC-K Parts & Service Telephone 800 Edition 06/99SFC-K Parts and Service Department Table of Contents Safety instructions Safety instructionsSFC-K Explanations and information Installation instructions SFC-K Transport Installation Compressed air supply Electrical connection 24VDC Maintenance SFC-K Maintenance intervals Cleaning the collecting bin Replacing/cleaning the filter cartridge in the hopper loader SFC-K Nonreturn valve Replacing the sealing ringsOutlet flap Purchase order number Filter cartridge Technical data Technical dataAppendix Spare parts list SFC-K 40/50 Pos Orderno. / Designation