Sterling SFC-K 50, SFC-K 40 Replacing/cleaning the filter cartridge in the hopper loader

Page 20

SFC-K

3.3. Replacing/cleaning the filter cartridge in the hopper loader

»

Stop the conveying procedure.

Switch off the conveying system at the main switch.

Interrupt the mains supply.

Set all compressed-air lines at zero pressure.

&

The conveying capacity is diminished by a clogged filter car- tridge.

Open the toggle-type fasteners (A) between the hopper lid and the hopper loader.

Remove the hopper lid with the fil- ter cartridge (B) from the hopper loader.

Remove the locking pin and open the lock nut on the filter cartridge

(B).

Remove the filter cartridge (B) from the hopper lid.

Blow compressed air through the clogged filter cartridge from the in- side out or replace the filter car- tridge (B).

SM3-635b

A

B

SFC-K

Maintenance 19

Image 20
Contents Operating Instructions Safety Filters SFC-K Sterling Material ProcessingParts & Service Telephone 800 Edition 06/99 SFC-KSFC-K Parts and Service Department Table of Contents Safety instructions Safety instructionsSFC-K Explanations and information Installation instructions SFC-K Transport Installation Compressed air supply Electrical connection 24VDC Maintenance SFC-K Maintenance intervals Cleaning the collecting bin Replacing/cleaning the filter cartridge in the hopper loader SFC-K Replacing the sealing rings Nonreturn valveOutlet flap Purchase order number Filter cartridge Technical data Technical dataAppendix Spare parts list SFC-K 40/50 Pos Orderno. / Designation