Fish Sensitivity

Fish Sensitivity adjusts the threshold of the Fish ID+TM detection algorithms. Selecting a higher setting allows weaker returns to be displayed as fish. This is useful for identifying smaller fish species or baitfish. Selecting a lower setting displays fewer fish from weak sonar returns. This is helpful when seeking larger species of fish. Fish Sensitivity is used in conjunction with Fish ID+TM. Fish ID+TM must be On for Fish Sensitivity to affect the ability of the Fishing System to identify sonar returns as fish.

To change the Fish Sensitivity setting:

1.Highlight Fish Sensitivity on the Sonar main menu.

2.Use the LEFT or RIGHT 4-WAY Cursor Control keys to change the Fish Sensitivity setting. (Low = 1, High = 10, Default = 5)

Real Time Sonar (RTS®) Window

RTS® Window sets the RTS® Window to either Wide or Narrow, or turns it off in the Sonar View. The RTS® Window always updates at the fastest rate possible and only displays returns that are within the transducer beam. (See Real Time Sonar (RTS®) Window for additional detail).

RTS® Window (Wide)

RTS® Window (Narrow)

RTS® Window (Off)

To change the RTS® Window setting:

1.Highlight RTS Window on the Sonar main menu.

2.Use the LEFT or RIGHT 4-WAY Cursor Control keys to change the RTS® Window setting. (Wide, Narrow, Off, Default = Wide [Default = Off for Matrix 10])

83 kHz Sensitivity

(Advanced: DualBeam PLUS™and QuadraBeamTM Only)

83 kHz Sensitivity changes the sensitivity of the 83 kHz beam. Increasing the 83 kHz Sensitivity will display additional weak returns and decreasing the 83 kHz Sensitivity will display fewer weak returns. The 83 kHz Sensitivity menu choice is only available when User Mode is set to Advanced (see Setup Menu Tab: User Mode).

To set the 83 kHz Sensitivity:

1.Make sure you are in Advanced User Mode, then highlight 83 kHz Sensitivity on the Sonar main menu.

2.Use the LEFT or RIGHT 4-WAY Cursor Control keys to set the 83 kHz Sensitivity. (-10 to +10, Default = 0)

455 kHz Balance

(Advanced: QuadraBeamTM Only)

455 kHz Balance adjusts the sensitivity of the 455 kHz beam. Increasing the sensitivity will display additional weak returns and decreasing the sensitivity will display fewer weak returns. The 455 kHz Balance menu choice is available when User Mode is set to Advanced (see Setup Menu Tab: User Mode).

To change the 455 kHz Balance setting:

1.Make sure you are in Advanced User Mode, then highlight 455 kHz Balance on the Sonar Main Menu.

2.Use the LEFT or RIGHT 4-WAY Cursor Control keys to change the 455 kHz Balance. (-10 to +10, Default = 0)

31

32

Image 19
Contents Operations Manual Thank You Table of ContentsSonar Menu Tab Alarms Menu TabSetup Menu Tab Accessories Menu Tab TroubleshootingQuadraBeam Sonar How Sonar WorksSingle Beam Sonar DualBeam Plus SonarSoft Bottom What’s On the DisplayBait Ball Hard BottomSonar View ViewsSonar View Understanding Sonar HistorySonar Zoom View Real Time Sonar RTS WindowSonar Zoom View Full range view200/83 kHz Split Sonar View 200/83 kHz Split Sonar ViewBig Digits View DualBeam Plus and QuadraBeamTM OnlyDigital readouts in the Side Beam View cannot be customized Side Beam ViewBottom Presentation QuadraBeamTM OnlyKey Functions POWER/LIGHT KeyView Key WAY Cursor Control Key Menu KeyExit Key Powering Up the Unit Accessory BusMenu System Normal Operation Start-Up Options MenuWith PC Connect Cable Only SimulatorSystem Status PC ConnectSensitivity To adjust the SensitivityTo adjust the Upper Range Sonar X-PressTMMenuLower Range Chart SpeedBottom View Sonar Zoom View Only To adjust the Zoom LevelZoom Level Sonar Menu TabHighlight Beam Select on the Sonar main menu Beam SelectFish ID+TM To use Beam SelectKHz Sensitivity Fish SensitivityKHz Balance Surface Clutter To change the Depth Lines settingTo change the Surface Clutter setting Depth LinesTransducer Select Noise FilterMax Depth Water TypeLow Battery Alarm Alarms Menu TabDepth Alarm Fish ID AlarmUnits Distance Setup Menu TabUnits Depth Units TempUnits Speed User ModeTriplog Reset Restore DefaultsSelect Readouts Select ViewsTemp Offset To change the Depth Offset settingTo change the Temp Offset setting Depth OffsetSpeed Calibration Accessories Menu TabNmea Output Control head loses power at high speeds TroubleshootingDisplay Problems Problem Possible CauseFinding the Cause of Noise Matrix Fishing System AccessoriesIsolation Specifications Contact Humminbird