Humminbird Model Matrix 87 manual Sonar X-Press Menu, Side View, Sensitivity, Sonar Views Only

Page 22

M87_Man_531352-1_A.qxd 12/9/2004 3:28 PM Page 42

Sonar X-Press™ Menu

(Sonar Views Only)

The Sonar X-Press™ Menu provides access to the settings most frequently-used. Press the MENU key once while in any of the Sonar Views to access the Sonar X-Press™ Menu.

NOTE: Menu choices will vary depending on system settings such as whether the unit is set for Advanced User mode or what transducer is currently selected.

Sonar X-Press™ Menu

Side View

(WideSide® Transducer: WideSide® View Only)

Side View sets which transducer beam from the WideSide® Transducer is shown in the WideSide® View. A WideSide® transducer must be connected to the Matrix™ Fishing System. The Side View menu choice is available when Transducer Select is set to WideSide® (see Sonar Menu Tab: Transducer Select) and can only be accessed from the Sonar X-Press™ menu when you are in WideSide® view.

NOTE: The WideSide® View requires the purchase of the WideSide® transducer. You can visit our website at www.humminbird.com to order this accessory online or contact our Customer Resource Center at 1-800-633-1468.

To adjust the Side View:

1.Make sure you are in WideSide® Transducer Mode and that a WideSide® transducer is connected, then highlight Side View on the Sonar X-Press™ menu.

2.Use the LEFT or RIGHT 4-WAY Cursor Control keys to change the Side View setting. (L [Left], Both, R [Right], Default = Both)

Sensitivity

Sensitivity controls how much detail is shown on the display. Increasing the sensitivity shows more sonar returns from small baitfish and suspended debris in the water; however, the display may become too cluttered. When operating in very clear water or greater depths, increased sensitivity shows weaker returns that may be of interest. Decreasing the sensitivity eliminates the clutter from the display that is sometimes present in murky or muddy water. If Sensitivity is adjusted too low, the display may not show many sonar returns that could be fish.

Sensitivity at Low

Sensitivity at Medium

Sensitivity at High

To adjust the Sensitivity:

1.Highlight Sensitivity on the Sonar X-Press™ menu.

2.Use the LEFT or RIGHT 4-WAY Cursor Control keys to increase or decrease the Sensitivity setting. (Low = 1, High = 20, Default = 10)

36

37

Image 22
Contents Matrix 87c Operations Manual Table of Contents Thank YouSonar X-Press Menu Sonar Views Only Alarms Menu TabSetup Menu Tab Navigation X-Press Menu Navigation Views OnlyDualBeam Plus Sonar How Sonar WorksQuadraBeam Sonar Multi-Media Card MMC WideSide SonarHow GPS and Cartography Work With Optional-Purchase WideSide TransducerWhat’s On the Sonar Display KHz Blue Fish SymbolKHz Orange Fish Symbol High Sonar Intensity Return Bait BallSonar View ViewsSonar views Real Time Sonar RTS Window Understanding Sonar HistoryBottom Presentation Sonar Zoom View 200/83 kHz Split Sonar ViewBig Digits View Big Digits ViewSide Beam View Side Beam ViewBird’s Eye View WideSide ViewBird’s Eye View Combo View Chart ViewChart View with Active Cursor View OrientationWaypoints, Routes and Tracks Viewing CartographyIntroduction to Navigation Waypoints, Routes and TracksSave, Edit, or Delete a Waypoint Navigate to a Waypoint or PositionChart View with Grid Chart View with TargetAdd a Waypoint Target or Trolling Grid Save or Clear a Current Track Save, Edit or Delete a RouteEdit, Delete or Hide Saved Tracks View Key POWER/LIGHT KeyKey Functions Info KeyGoto Key Accessory BusPowering Up the Unit Zoom +/- KeySonar Tab, Normal Mode Sonar Tab, Advanced Mode Main Menu System Normal User ModeMenu System Start-Up Options Menu Exit Normal operation by powering your Matrix offExit the Simulator by powering your Matrix off Normal OperationSystem Status Exit PC Connect mode by powering the Matrix offPC Connect Sensitivity Sonar X-Press MenuSide View Sonar Views OnlyLower Range Chart SpeedUpper Range Side Beam RangeNavigation X-Press Menu To adjust the Bottom ViewBottom View Navigation Views OnlyClear Current Track Cancel NavigationSave Current Track Save Current RouteSonar Menu Tab Remove GridSonar Window Only if a Grid is ActiveTo use Beam Select Beam SelectFish ID+ Highlight Beam Select on the Sonar main menuKHz Balance Fish SensitivityKHz Sensitivity WideSide SensitivitySurface Clutter Depth LinesNoise Filter Transducer Select Max DepthWater Type Navigation Menu TabWaypoints TracksRoutes Lat/Lon Grid Chart Detail LevelMap Borders Spot SoundingsTrack Min Distance Grid RotationTrackpoint Interval Map DatumDelete All Nav Data Alarms Menu TabClear Map Offset To Clear Map OffsetLow Battery Alarm Depth AlarmFish ID Alarm Temp AlarmDrift Alarm Arrival AlarmAlarm Tone Units Temp Setup Menu TabUnits Depth Units DistanceRestore Defaults User ModeTriplog Reset Units SpeedTemp Offset Select ReadoutsDepth Offset Speed CalibrationPosition Format Local Time ZoneDaylight Savings Time Time FormatNmea Output SonarMatrix Doesn’t Power Up Accessories Menu TabTroubleshooting Matrix Defaults to Simulator with a Transducer AttachedFinding the Cause of Noise Display ProblemsProblem Possible Cause IsolationMatrix Accessories SpecificationsContact Humminbird