Humminbird Wide 2000 manual Sensitivity

Page 27

All menus use the same basic layout as shown in figure F. The heading at the top describes the menu function (see Menu Functions for more details on individual functions). The UP ARROW and DOWN ARROW symbols to the left of the menu indicate which buttons are available for adjustment. In menus which have numerous possible settings such as Depth Range, a range of adjustment indicator shows the total range available and the current setting. Within the menu are the options available. The selected option or current setting is highlighted in the black box.

If no adjustment is made, this will be the selected setting. Pressing one of the ARROW buttons while the menu is on-screen selects another option.

Several of the menus are multi-step. In some situations if an adjustment is made, additional options become available for further adjustment. Examples of these multi-step menus are Depth Range, Depth Alarm and Zoom. See the detailed description of each function for further explanation.

The one menu option which functions differently than the previously described is the Options menu. User Options is a group of functions which are used initially to select user preferences. The options are not normally needed during operation of the unit. Options differ from the other menu functions in that once selected for viewing, the menu will not ‘time out”. All the user options must be sequenced through before returning to normal operation.

SENSITIVITY

The Sensitivity function controls the sensitivity of the sonar receiver. The Wide 2000 automatically adjusts the level of receiver sensitivity based on a number of factors including the depth of the water and the level of noise present. Noise can be caused by other electronic devices, engines, trolling motors, propeller cavitation and hydrodynamic flow among others.

The user has the option of biasing this Sensitivity adjustment either higher or lower based on personal preference. You can select one of 11 sensitivity bias settings from –5 to +5. A bias setting of 0 ( Factory Setting) has no effect on the automatic sensitivity control.

Image 27
Contents Page Accessories Installation OverviewParts Supplied Determining How to Mount the Transducer Thru-Hull Mounting Alternate Transducers and Mounting MethodsPortable Mounting Trolling Motor MountingTransducer Exchange Beginning InstallationStep One Determine Where to Mount the Transducer Transom InstallationStep Three Assemble the Transducer Step Two Drill the Mounting HolesStep Five Adjust the Running Position of the Transducer Step Four Mount the Transducer to the TransomConfirm the pivot angle has not changed Step Six Route the Cable Inside the Hull Installation Step One Determine the Mounting LocationStep Two Test the Mounting Location Page Step Three Permanently Mount the Transducer Control Head Installation Step One Determine Where to MountStep Two Connect the Power Cable to the Boat Page Step Four Run the Cables Step Three Drill the Mounting HolesPage Your Humminbird is now ready for operation Step Five Assembling the Connector HolderTest the Installation Testing the Installation Simulator Operation Using the WideFeature Memory Interpreting the ON-SCREEN Information Page Page Control Functions Page Sensitivity Depth Range Page Zoom Depth Alarm Fish Alarm Triplog Page Page Page Page Customizing SET-UP Functions Using DiagnosticPage Using Alternative Transducers Specifications