Curtis 2200R, 2100R manual Operating Current, Variable Parameters

Page 7

Operating Current

Total system current is a function of the voltage,

!

sender type, display mode, and the gage’s factory

programming. Typical operating currents (not

 

including the current to drive the sender) vary from 16-55 mA, for 12V models, depending on model number. For 24V models, typical operating currents (not including the current to drive the sender) vary from 18-45 mA, depending on model number.

Variable Parameters

The following parameters are set in the factory as part of the gage’s programming. Contact Curtis for additional information on your specified model number.

Sender input: Variable resistance Variable voltage Variable current

Display mode

Single LED pointer* Rising bar graph

Transition points for each of the 10 LEDs

(Used to customize display for OEM applications)

*indicates standard setting

6

Image 7
Contents Read Instructions Carefully Model 2100RSafety Instructions Table of Contents 2111RXX-YYYY ZZ Model EncodementPage Accuracy Technical SpecificationsElectrical Operating Voltage Operating VoltagesVariable Parameters Operating CurrentIndicates standard setting Mechanical Output signal formatEnvironmental Temperature Salt spray fog VibrationHumidity Water/dust immunityTerminal Assignment For Models 2111R, 2112R, 2113R InstallationTerminal Assignments for Models 2211R, 2212R, 2213R Terminal Assignment for Model 2114RTerminal Assignments for Model 2214R Problem Possible Cause TroubleshootingMaintenance All specifications are subject to change Without notice Curtis INSTRUMENTS, INC