Siemens P technical specifications ≤ 0,1% ≤ 0,2% 10 r ≤, ≤ 0,2% ≤ 0,4% 30 r ≤ ≤ 0.005 ⋅ r + 0.05%

Page 35

 

 

© Siemens AG 2008

 

 

 

 

 

 

 

 

 

 

 

SITRANS P measuring instruments for pressure

 

 

 

 

Transmitters for food, pharmaceuticals and biotechnology

 

 

 

 

 

 

 

SITRANS P300 for gage and absolute pressure

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

SITRANS P300 for gage pressure and absolute pressure

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

HART

 

 

 

 

 

 

PROFIBUS PA and FOUNDATION Fieldbus

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Input of absolute pressure, with front-flush diaphragm

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Measured variable

 

Absolute pressure (front-flush)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

2

Spans (infinitely adjustable) or

 

Span

 

Max. perm. test pres-

 

Nominal measuring

 

Max. perm. test pres-

 

 

 

 

 

 

nominal measuring range and

 

 

 

sure

 

 

range

 

sure

 

 

 

 

max. pemissible test pressure

 

43 ... 1300 mbar a

 

10 bar a

 

 

1300 mbar a

 

10 bar a

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

(0.62 ... 18.9 psi a)

 

(145 psi a)

 

 

(18.9 psi a)

 

(145 psi a)

 

 

 

 

 

 

 

0.16 ... 5 bar a

 

30 bar a

 

 

5 bar a

 

30 bar a

 

 

 

 

 

 

 

 

 

 

 

 

 

 

(2.32 ... 72.5 psi a)

 

(435 psi a)

 

 

(72,5 psi a)

 

(435 psi a)

 

 

 

 

 

 

 

1 ... 30 bar a

 

100 bar a

 

 

30 bar a

 

100 bar a

 

 

 

 

 

 

 

(14.5 ... 435 psi a)

 

(1450 psi a)

 

 

(435 psi a)

 

(1450 psi a)

 

 

 

 

 

 

 

Depending on the process connection, the span

 

Depending on the process connection, the nomi-

 

 

 

 

may differ from these values

 

 

nal measuring range may differ from these values

 

 

Lower measuring limit

 

0 bar a (0 psi a)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Upper measuring limit

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

• Measuring cell with silicone oil

 

100% der max. Messspanne

 

 

100% des max. Nennmessbereichs

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Output

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Output signal

 

4 ... 20 mA

 

 

 

 

 

 

Digital PROFIBUS PA signal

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Physical bus

 

-

 

 

 

 

 

 

IEC 61158-2

 

 

 

 

 

 

 

With polarity reversal protection

 

No

 

 

 

 

 

 

Yes

 

 

 

 

 

 

 

Electrical damping T63 (step width 0.1 s)

 

Set to 0.1 s (0 ... 100 s)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Accuracy

 

To EN 60770-1

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Reference conditions

 

Increasing characteristic, start-of-scale value 0 bar, stainless steel seal diaphragm, measuring cell

 

 

(All error data refer always refer to the set

 

with silicone oil, room temperature 25 °C (77 °F), span ratio (r = max. span / set span)

 

 

 

 

 

span)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Measurement deviation with cut-off point set-

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

ting, including hysteresis and repeatability.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Gage pressure

 

Absolute

 

(Absolute

 

Gage pressure

 

Absolute

 

(Absolute

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

pressure

 

pressure,

 

 

 

pressure

 

pressure,

 

 

 

 

 

 

 

 

 

front-

 

 

 

 

 

front-

 

 

 

 

 

 

 

 

 

flushed)

 

 

 

 

 

flushed)

 

 

Linear characteristic curve

 

 

 

 

 

 

 

 

0,075%

 

0,1%

 

0,2%

 

 

• r 10

 

(0.0029 r + 0.071)%

 

0,1%

 

0,2%

 

 

 

 

 

 

 

 

 

• 10 < r 30

 

(0.0045 r + 0.071)%

 

0,2%

 

0,4%

 

 

 

 

 

 

 

 

 

• 30 < r 100

 

(0.005 r + 0.05)%

 

-

 

 

-

 

 

 

 

 

 

 

 

 

Settling time T63 without electrical damping

 

Approx. 0.2 s

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Long-term drift at ± 30 °C (± 54 °F)

 

(0.25 r)%/5 years

 

(0.1 r)%/year

 

0.25%/5 years

 

0.1%/year

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Influence of ambient temperature

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

• at -10 ... +60 °C (14 ... 140 °F)

 

(0.1 r +0.2)%

 

 

 

 

(0.2 r

 

0,3%

 

 

 

0,5%

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

+0.3)%

 

 

 

 

 

 

 

 

 

• at -40 ... -10 °C and +60 ... +85 °C

 

(0.1 r + 0.15)% / 10 K

 

 

 

 

(0.2 r +

 

0.25%/10 K

 

 

 

0.5%/

 

 

(-40 ... 14 °F and 140 ... 185 °F)

 

 

 

 

 

 

0.3)%/10 K

 

 

 

 

 

10 K

 

 

Influence of the medium temperature (only

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

with front-flush diaphragm)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

• Temperature difference between medium

 

3 mbar/10 K (0.04 psi/10 K)

 

 

 

 

 

 

 

 

 

 

temperature and ambient temperature

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Siemens FI 01 · 2009

2/35

Image 35
Contents Differential pressure Sitrans P AccessoriesProduct overview Transmitters for gage, absoluteOverview Product overviewSitrans P measuring instruments for pressure Series for gage pressure Mode of operationTransmitters for gage, absolute and differential pressure Schematics Technical specificationsDimensional drawings Series for gage and absolute pressure Rated operating conditions Power supply UHAccuracy  For absolute pressure With metal measuring cellMbar g psi g1 Up to Bar psi g1Explosion protection Output signalMeasuring range Measuring ranges for absolute pressure only for US marketE10 Sealing material between sensor and housingProcess connection C11Sitrans P250 differential pressure transmitter Application Sitrans P250 for differential pressureTechnische Daten Certificates and approvals Approval Conditions of useConnection 1 +UB Male thread G1/8-a = CuZn nickel-plated Width across FlatsMm inch Inch mm Female thread G1/8 Stainless steel 1.4305/AISIAvailable ex stock Siemens FI 01 · Accuracy ≤ 1 %, wetted parts ceramic/stainless steelSealing material Functions ZD series for gage and absolute pressureDisplays and controls Power supplyType a Selection and Ordering data Order Code Series for gage and absolute pressureInput variable Measured range SpanOverview Application Sitrans P Compact For gage and absolute pressureTransmitters for food, pharmaceuticals and biotechnology Diaphragm seal With aseptic connection Diaphragm seal With quick-release clampFilling liquid Sitrans P Compact pressure transIntegral cooling element K01 Measured range Overload pressureMeasured range Overload pres Sure Hygiene version P01Clamp-on seal With aseptic connection ISO pipes to ISO Measured rangeSitrans P Compact, connection diagram Siemens FI 01 · Dimensional drawings HousingSitrans P, dimensions in mm inch Absolute pressure Sitrans P300 for gage and absolute pressureGage pressure LevelElectronics Function diagram of electronicsDesign Function Device comprises Operation of the electronics with Hart communicationTion Electronics Mode of operation of the measuring cellsOperation of the electronics with Profibus PA communica Measuring cell for absolute pressure, function chart Measuring cell for gage pressure, function chartParameters Input keys Hart com Munication Physical variable Physical dimensionsParameterization of Sitrans P300 Fieldbus interface Parameters Input keys Profibus PAAbsolute pressure input Sitrans P300 for gage pressure and absolute pressureProfibus PA and Foundation Fieldbus Gage pressure inputWith front-flush diaphragm ≤ 0,1% ≤ 0,2% 10 r ≤≤ 0,2% ≤ 0,4% 30 r ≤ ≤ 0.005 ⋅ r + 0.05% ≤ 0.2 ⋅ r + ≤ 0.25%/10 K ≤ 0.5% 140 .. FDesign version with front-flush dia Phragm +150 CDesign standard version Transmitters for food, pharmaceuticals and biotechnology Communication Foundation Fieldbus Hart communicationProfibus PA communication Measuring cell filling Selection and Ordering data Order No20 mA/HART Foundation Fieldbus FFStainless steel, deep-drawn and electrolytically Polished Foundation Fieldbus FF F 8 1 2Seal diaphragm Measuring cell Stainless steel See Further designsCable socket for M12 plug Temperature decoupler up to 200 C7 P00Temperature decoupler up to 250 C P10 Mounting bracket A02Q64 Setting of pressure indication in pressure Y21 UnitsPreset bus address Y25 Q63Sitrans P300, with oval flange, dimensions in mm inch Sitrans P300, front-flush, dimensions in mm inch NuG and pharmaceutical connections Flanges to EN and AsmeAseptic flange with notch to DIN 11864-2 Form a Thread connection G¾, G1 and G2 to DINTank connection TG52/50 und TG52/150 IDF socket with union nutSitrans P, DS III series Transmitters for gage pressure for the paper industryDevice front view, Sitrans P DS Transmitters for gage pressure for the paper industryFunction Parameterization Measuring cell for gage pressure with front-flush diaphragmLmp, gallon, bushel, barrel, barrel Pressure setting can also beAdjustable parameters Input keys Profibus PA Temperature F, R Miscellaneous Siemens FI 01 ·Profibus PA or Foundation Fieldbus Output signal 20 mASignal DS III series with PMC connectionTo EN 61326 and Namur NE Munity Transmitters for gage pressure for the paper industryAnalog input Adaptation to customer-specif Electrical connection / cable inlet Series DS III Hart Measuring cell filling CleaningMeasuring cell filling Cleaning Nominal measuring rangeP02 M12 cable sockets metal A50 Rating plate inscriptionB11 C11 Bration to IEC Acceptance test certificate C1226.3 mm Approx 33.1 mm PMC Style standard40.9 mm Approx 36.8 mm PMC Style miniboltTo EN 61326 and Namur NE Siemens FI 01 · Sitrans P300 with PMC connectionTransmitters for gage pressure for the paper industry Perature Simulation function Available Reset function due to meteringHart communication 230 .. Ω Protocol BytesY22 + Sure units Y01 40.4 mm Approx 36.8 mm DS III, DS III PA and DS III FF series Technical description Front view Pressure transmitter for gage pressureFunction diagram of the electronics Measuring cell for gage pressure Measuring cell for gage pressure, function diagramMeasuring cell for level, function diagram G/min, g/s, lb/d, lb/h, lb/min, lb/s Parameterization DSParameters Input keys Hart com MmH2O, ftH2O 20 C, inHg, mmHgTemperature F, R Miscellaneous Siemens FI 01 · DS III series For gage pressure Sitrans P, DS III series for gage pressure T4...T6 CL II, DIV 2, GP FG CL Siemens FI 01 · Classification according to pressure equipInternal preprocessing Device profile EEx ia + EEx d6 Ex nA/nL zone Display Without indicatorSilicone oil Standard Inert liquid1 Grease-free Bar g 15 .. .5 psi g Psi g 102.0 ...10153 psi gScrewed gland M20x1.5 Screwed gland ½-14 NPT Plug M12 metal6 EEx ia + EEx d5 Ex nA/nL zoneSetting of pressure indication Y22 + Non-pressure units Y01 Digital indicator alongside the input keys D27Explosion-proof Intrinsic safety to E25 Inmetro Brazil Explosion-proof Intrinsic safety to E55 Nepsi ChinaDimensional drawings Sitrans P measuring instruments for pressure Input absolute pressure, with front-flush Diaphragm 40 ... +200 C -40 ... +392 F Weight without options ≈ 1.5 kg ≈ 3.3 lb Housing material10 ... +85 C 14 ... +185 F 40 ... +150 C -40 ... +302 FEhedg Hart communication Bar g1 Psi g1 Mbar a2 Psi a2 Bar a2 Absolute pressure, front-flush membraneSeal diaphragm Connection shank Stainless steel Flange version with Order code M.., N.., R.. orM49 Threaded connection acc. to DIN Form a Temperature decoupler up to 200 C4 P00PROFIsafe certificate and protocol C21 Flanges to EN M48Additional data 300 255 mm Siemens FI 01 · 115 mm Approx 100 140 mm 52 mm 150 mm 170 mm 165 mm 200 mmAsme B16.5 Varivent connection IDF threaded socket Tank connection TG52/50 and TG52/150133 100 159 Aseptic threaded socket to DIN 11864-1 Form a95 x 1/6 110 x ¼ 100 130 x ¼ 113Profibus PA or Foundation Fieldbus Input Profibus PA or Foundation Fieldbus Profibus PA or Foundation Fieldbus Certificate and approvals Hart communication Pressure, from the pressure series DS III Hart Mbar a Psi a Bar a Hidden, setting mA With visible digital indicatorE55 China C11 Bration to IEC 60770-2 Acceptance test certificate2 C12Dimensional drawings Sitrans P measuring instruments for pressure Technical specifications Design 100 101 EEx ia + EEx d Ex nA/nL zone 102Pressure, from the differential pressure Casting6Casting 103104 Sealing screw with valve option 105106 464 psi InH 2O Mbar 160 bar DS III series for differential pressure and flow107 Wetted parts materials Seal diaphragm Weight without options ≈ 4.5 kg ≈ 9.9 lb Housing material108 109 Profibus PA or Foundation Fieldbus Power supply UHGraph 3 sound engineering practice PN 420 MWP 6092 psi 110111 PN 32 MWP 464 psi Mbar2 4015 .. .03 inH2O PN 32/160 MWP 464/2320 psi Measuring cell filling Cleaning112 Tial pressure and flow, Series DS III HartWetted parts materials stainless steel process flanges Zone 2 planned Intrinsic safety, explosion-proof enclosure113 PN 32 MWP 464 psi Mbar2 03 inH2O114 Y221 Non-pressure units Setting of pressure indicator in pressure Y21 Units115 Y02PN 420 MWP 6092 psi Display 116Silicone oil Standard 117 Y22 + Non-pressure units Y01 or 118Explosion-proof Zone 2 to Nepsi China E57 Max digits Y02 Up to Mbar, bar, kPa, MPa, psi119 120 121 Process connection ¼-18 NPT EN 61 Blanking plug 122123 Sitrans P, DS III series for level DS III series for level124 Yes Siemens FI 01 · 125To EN 61326 and Namur NE Nity Classification according to pressure equipment 126Mounting flange 127Process connection of low-pressure side 128Use on zone 1D / 2D E01 129Rings for process flanges on Low-pressure side A31 Sealing screwsTube length 130Y221 Non-pressure units + Y01 Mounting flange F 4 9 1= available 131Flame flashover lock-out A01 Tation200 138 160 150 or 220 115 158 180 235 162 190 132Nom. diam Nom. press 200 138 721 160 150 or 220 115 158 180 235 162 190 133Structural design Sitrans P AccessoriesSupplementary electronics for 4-wire connection 134E86060-K6017 Supplementary electronics for 4-wire Connection135 Output current136 Vent on side for gas measurements H02 Process flanges 137A23 Acceptance test certificate C12 Process connection G½A D16 Remote seal flanges D20Without process flanges K00 Replacement measuring cell for level F 4 9 9138 Rated measuring range139 140 141 Selection and Ordering data 142Valve manifolds mounted on Sitrans P DS 143144 Valve manifolds mounted on Sitrans P300 145Integration Transmitters for hydrostatic levelMPS series submersible sensor 146Cable hanger Application 147Junction box Application 148 7MF1570-5ZA02-Z 149More information Quick-release diaphragm seal Remote seals for transmitters and pressure gages150 DesignsMiniature diaphragm seal with diaphragm flush with front Temperature error151 Transmission responseRecommendations 152Response time 290 870 6000 Phragm seal G1½B 058 145 2000 Technical specifications Temperature error Diaphragm seals153 Inch Mbar Psi 10 K 10 K ⋅ m KapInch Mbar Psi 10 K 154155 Temperature error Clamp-on sealsMaximum temperature of medium Calculation of the temperature errorExample of temperature error calculation Dependence of temperature error on diaphragm materialResponse times Technical data of filling liquidsFilling liquid Density Temperature 157Diaphragm seals of sandwich design Diaphragm seals of sandwich design158 159 Connection to Asme B16.5 160Connection to EN Diaphragm seals of flange design with flexible capillary Diaphragm seals of flange design161 Length of capillary4 162To a pressure transmitter Sitrans P order separately 163 4404/316L B16.5 RF 125 .. AA For the other materials 164165 Nom Diam Press 166Pressure transmitter 167Diaphragm seal Mounting flange with tube as option for 168Mounting flange with tube as option for Flanged remote seal without tube, fitted byNom. Nom Diam. press 169200 138 160 DN 100 PN 158 180 235 162 190 Quick-release diaphragm seal Quick-release diaphragm sealsFor gage, absolute and differential pressure 170Vacuum-proof design V03 171Connection to pressure transmitter Connection to transmitter172 0 15 ³ RVacuum-proof design V01 Miniature diaphragm seal173 Miniature diaphragm sealsProcess connection Flushing ringsFor diaphragm seals 174Connection to Asme B 175Clamp-on seals for flange-mounting Clamp-on seals of flange designFor gage pressure, differential pressure and flow 176Delivery 1 off 177Class 178179 Remote seals Weight Approx kg approx .82 lbQuick-release clamp-on seals For pressure and absolute pressurePressure 7MF403 7 and 7MF423 7 together with Order 180For Sitrans P pressure transmitters for Clamp connection for pipes to BS 4825/3 and o.D. tubes 181Connection to DIN 11851 with screw necks 182 Measuring setupsRemote seals 183 Measuring setups with remote seals184 Types of installation for level measurements closed vessels185 Measuring setups without remote seals186 Measuring setups for closed containers187 Y01 188Values must be entered here Siemens FI 01 · 189Range Material acceptance test certificate to EN Fittings190 New standard DIN ENSelection of available shut-off valves Selection aid191 212 Tion DN 5/DN 8 for vapor Measurement 7MF9416-6 192Differential pressure transmit 201 Way valve manifolds 206193 Shut-off valves to DIN 16270, DIN 16271 and DIN194 Characteristic curvesShut-off valve, form B, dimension drawing, dimensions in mm Angle adapters 7MF9401-7WA Overview Dimensional drawingsAngle adapter 195196 Double shut-off valves197 Accessories for shut-off valves / double shut-off valves198 Way valve manifolds DN199 200 Connection diagram of the 2-way valve manifolds201 5-spindle valve manifolds DN202 203 Spindle valve manifold DN 5 7MF9411-5B., dimensions in mm204 Multiway cocks PNMultiway cock in oil-free and grease-free design Accessories Dimensional drawingsAccessory set for multiway cock PN 205For non-aggressive liquids For aggressive Gases Liquids Way and 5-way valve manifolds DN206 Overview Function207 BB C 208209 Component Material Mat. No Housing P250GH 0460 4571Way valve manifold DN For wall mounting or for securing on rack 72 mm grid Accessory set for 3-way valve manifold DN 8 for flangingFor pipe mounting, weight 0.7 kg M12 7MF9006-6GA 210211 Dimensional drawings SchematicsValve manifold DN Blow-out valves DN Valve manifold combination DN 5/DN212 Valve manifold combination DN 5/DN 8 for Vapors213 Valve manifold Blow-out valves Valve manifold combination DN214 Without test connection With test connection M20 × 215Functions 216Mounting clips 2 off 217218 Spindle valve manifold DN 5, connections Siemens FI 01 · 219Spindle valve manifold DN 5, connections M18 7MF9006-6PA Required for mounting on 2 stand 220Valve manifolds for vertical differential Pressure lines Mounting bracket Required for wall mounting or forMounting bracket for mounting on 2 standpipe Accessory set connection between manifold and transmitter221 222 223 Accessory set for low-pressure multiway cockLow-pressure multiway cock 224 OptionsCharacteristic curvesMounting bracket 7MF9004-6AA M13, dimensions in mm 225 Fittings AccessoriesOval flange 226 Adapters, connection glands227 Connection parts G 1/2Made Water traps, Sealing rings to EN228 M56340-A54 Pressure surge reducers229 Pressure surge reducer230 Shut-off valve 7MF9017-1A., dimensions in mmShut-off valve 7MF9017-1B. and -2B., dimensions in mm Primary shut-off valvesShut-off valve for aggressive liquids and gases 231X b 7MF9017 Shut-off valve for non-aggressive liquids, gases and vapors232 Compensation vessel 7MF9015-1.., dimensions in mmCompensation vessel 7MF9015-5.., dimensions in mm Compensation vessels233 Connection parts234
Related manuals