Nexus 21 manual Nexus Autopilot 1510 summary of known checkpoints, Checkpoints Power

Page 1

NEXUS Autopilot 1510 summary of known checkpoints

All Autopilot systems are complex systems dependant of a number of transducers and control algorithms why faultfinding needs to be done carefully to lead to correct remedy.

Checkpoints:

Power:

It is essential to Power the Pilot servo and the Pump motor to get current enough without risk of voltages drops.

Wireing can be effective by using Relay to get shorter length of cables.

15A fuse

+

-

Battery

=Power Wires

*) Not nessesary

3A fuse

Power switch for the Server

Emergency switch for the AP Servo

Relay

Optional power switch* for the AP Servo

NX2/Nexus

Server

+12V

0V

Autopilot

Servo 1510

+12V

0V

In a system without relay the Nexus system should never be powered up later than the AP Servo.

To avoid ”backdrain” of current do not connect the Green wire (+12V) from the Nexus system.

Wire thickness dependant of Power Cable length :

Cable Length

Wire Area

Wire Area

Max. m. (ft)

mm2

AWG

3

(10)

2,5

14

5

(16)

4

12

7,5

(25)

6

10

12

(40)

8

8

Image 1
Contents Nexus Autopilot 1510 summary of known checkpoints Checkpoints PowerRudder angle Transmitter RAT/RFU Check dip switchesHydraulics Remote ControlCompass transducer Auto-deviation