Univex 4505-7, 4505MP1, 4505-1, 69370 Wiring Instructions, Care and Maintenance

Page 2

WARNING: Do not allow sealants containing acetic acid (smells like vinegar) such as silicone rubber sealant to contact the plastic pump housing or thru-hull connector. Such sealants can attack the plastic, causing the pump housing to crack, resulting in pump failure.

5.Insert thru-hull connector through the hole and tighten to hold the thru-hull connector firmly in place. CAUTION: Do not overtighten the nut.

WIRING INSTRUCTIONS

WARNING: Be certain that power source is 12-volt D.C. Higher voltage will damage the pump.

1.Using the full length of wire provided (and additional wire if necessary), connect wires to the pump as shown in the diagram. (See Figure 2.)

Figure 2

 

 

Black

 

Manual

Brown/White or Tan

 

 

 

Off

 

12 Volt Battery

Automatic

Brown

 

 

Suitable Fuse

3-Way Switch

Test Knob

(see chart)

#7615A

 

2.Route wires out of the way and secure them to the bulkhead to avoid pulling.

3.Using butt connectors sized for 16-gauge wire, splice fuse holder into positive lead (brown) between the battery and switch. Position fuse holder in a location that is easily accessible for changing fuses.

IMPORTANT: Use fuses of the proper amperage (See Specification Chart at top of sheet).

WARNING: FAILURE TO PROPERLY FUSE AND MAKE THE APPROPRIATE WATERPROOF CONNECTIONS WILL VOID THE PRODUCT WARRANTY.

4.Install a Three-Way Switch (Attwood No. 7615A) that allows for automatic or manual switching modes.

5.Turn the pump on and twist the Test Knob clockwise to check operation. Feed water into the pump. If output appears to be too low, check the wire connections. Reversed connections result in opposite impeller rotation that drastically reduces capacity and can cause premature pump failure.

CARE AND MAINTENANCE

Occasionally check your pump to be certain debris is not jamming the impeller and/or float within the housing. Use the test knob by rotating in a clockwise direction. Careful attention will guarantee outstanding pump performance.

To clean the water chamber, remove pump housing from the mounting base by pressing in tabs on sides. Lift the pump housing away. (See Figure 3.)

To clean the impeller, remove the impeller guard screw and lift the impeller guard.

Figure 3

Impeller Guard

Remove (1)Screw

Depress (2)Tabs

Remove all debris that has accumulated in pump chamber and around the impeller. Ensure that all debris is removed from strainer slots around the pump base.

Inspect the impeller to ensure that it is firmly attached to shaft and is not cracked or broken.

Replace impeller guard, screw, and pump housing on base. Be certain that all tabs are fully engaged.

Periodically check the electrical connections to ensure they are water-resistant and mounted high and dry.

Do not use household cleaners on the pump because many of them may damage the pump materials.

ATTWOOD LIMITED WARRANTY

ATTWOOD CORPORATION, 1016 North Monroe, Lowell, Michigan 49331 (ÒAttwoodÓ) warrants to the original consumer purchaser that Attwood brand products will be free from defects in materials and workmanship under normal use and service for three years from the date of original consumer purchase. This warranty does not extend to any batteries or fuses used with the product. This limited warranty is not applicable if the product has been damaged by accident, improper installation, unreasonable or improper use, lack of proper maintenance, unauthorized repairs or modifications, normal wear and tear, or other causes not arising out of defects in materials or workmanship. Attwood products are warranted for use on pleasure boats. Any other use Ñ including but not limited to commercial, racing, or non- marine use Ñ are not covered under this warranty. AttwoodÕs obligation under this warranty is limited to repair of the product at AttwoodÕs plant or replacement of the products at AttwoodÕs option without expense to the original consumer purchaser. Any expenses involved in the removal, reinstallation or transportation of the product are not covered by this warranty. The product must be returned to AttwoodÕs plant at the address above, postage prepaid, and insured with proof of original purchase including date. If Attwood is unable to replace the product and repair is not commercially practical or cannot be timely made, or if the original consumer purchaser is willing to accept a refund in lieu of repair or replacement, Attwood may refund the purchase price, less an amount for depreciation. The acceptance by Attwood of any product returned or any refund provided by Attwood shall not be deemed an admission that the product is defective or in violation of any warranty. Products that are replaced or for which a refund is issued become the property of Attwood.

THIS WARRANTY IS ATTWOODÕS ONLY EXPRESS WARRANTY OF THIS PRODUCT. NO IMPLIED WARRANTY SHALL EXTEND BEYOND THREE (3) YEARS FROM THE DATE OF ORIGINAL CONSUMER PURCHASE. ATTWOOD SHALL NOT BE LIABLE FOR ANY DAMAGES, FOR LOSS OF USE OF THIS PRODUCT, NOR FOR ANY OTHER INCIDENTAL OR CONSEQUENTIAL DAMAGES, COSTS OR EXPENSES.

Some states do not allow limitations on how long an implied warranty lasts or the exclusion or limitation of incidental or consequential damages, so the above limitations and exclusions may not apply to you. This warranty gives you specific legal rights, and you may have other rights which vary from state to state.

© 2003 Attwood Corporation

1016 N. Monroe Street, Lowell, MI 49331-0260 www.attwoodmarine.com

Image 2
Contents Optional Materials THRU-HULL Connector InstructionsRequired Materials Pump Mounting InstructionsWiring Instructions Care and MaintenanceMatériel Facultatif Conservez CES DirectivesAvertissement Directives DE Fixation DE LA PompeDirectives DE Filage Soin ET Entretien