PRECAUTIONS

DO NOT BEGIN INSTALLATION UNTIL YOU READ THE FOLLOWING PRECAUTIONS.

!WARNING

If you do not follow these instructions exactly, a fire or explosion may result, causing property damage, personal injury or loss of life.

1.Failure to turn off electric or main gas supply to heating system could cause personal in- jury and/or property damage by shock, gas suffocation, fire, and/or explosion.

2.Do not use this control on circuits exceeding specified voltage. Higher voltage will damage the control and may cause shock or fire hazard.

3.NEVER USE FLAME OR ANY KIND OF SPARK TO CHECK FOR GAS LEAKS–COULD CAUSE FIRE AND/OR EXPLOSION.

4.DO NOT USE WIRE JUMPER on pilot sys- tems, such as standing pilot, proven pilot, or spark-to-pilot ignition–a fire and/or explosion may result.

5.Do not use a control set for natural gas with LP gas, or a control set for LP gas with natural gas. Personal injury and/or property damage, gas suffocation, fire, and/or explosion may result.

!CAUTION

1.Do not short out terminals on gas valve or primary control to test. Short or incorrect wiring can cause equipment damage, prop- erty damage, and/or personal injury.

2.This control is not intended for use in loca- tions where it may come in direct contact with water. Suitable protection must be provided to shield the control from exposure to water (dripping, spraying, rain, etc.).

2

Image 2
Contents Description Installation InstructionsSpecifications Precautions Installation System Wiring Main Piping ConnectionsAdjustment Pilot GAS Adjustment Pilot Lighting