25HPA6
Table 1 – Refrigerant Connections and Recommended Liquid and Vapor Tube Diameters (in.)
| LIQUID |
| RATED VAPOR* | |
UNIT SIZE |
|
|
|
|
Connection | Tube | Connection | Tube | |
| Diameter | Diameter | Diameter | Diameter |
|
|
|
|
|
25HPA624 | 3/8 | 3/8 | 3/4 | 3/4 |
25HPA636 | 3/8 | 3/8 | 7/8 | 7/8 |
25HPA648 | 3/8 | 3/8 | 7/8 | |
25HPA660 | 3/8 | 3/8 | 7/8 |
* Units are rated with 25 ft. (7.6 m) of lineset. See Product Data sheet for performance data when using different size and length linesets.
Notes:
1.Do not apply capillary tube indoor coils to these units.
2.For Tubing Set lengths between 80 and 200 ft. (24.38 and 60.96 m) horizontal or
20 ft. (6.1 m) vertical differential, refer to the Residential Piping and Longline Guideline using Puron refrigerant.
Table 2 – Accessory Usage
| REQUIRED FOR | REQUIRED FOR LONG LINE | REQUIRED FOR SEA | |
| ||||
ACCESSORY | APPLICATIONS* | COAST APPLICATIONS | ||
APPLICATIONS | ||||
| (Over 80 ft/24.38 m) | (Within 2 miles/3.22 km) | ||
| (Below 55°F/12.8_C) | |||
|
|
| ||
Crankcase Heater | Standard | Standard | Standard | |
| Standard with Infinityt Control | No |
| |
Evaporator Freeze Protection | (Low Ambient not allowed with non | No | ||
| communicating thermostat) |
|
| |
No | Yes | No | ||
| Standard with Infinity Control (Low | No |
| |
ambient not allowed with non | No | |||
| nicating thermostat) |
|
| |
Puron Refrigerant Balance Port | Yes{ | Yes{ | Yes{ | |
|
|
| ||
Support Feet | Recommended | No | Recommended | |
| Standard with Infinity Control | No |
| |
Winter Start Control | (Low Ambient not allowed with non | No | ||
| communicating thermostat) |
|
|
*For tubing set lengths between 80 and 200 ft. (24.38 and 60.96 m) horizontal or 20 ft. (6.10 m) vertical differential (total equivalent length), refer to the Long Line
{Required on all indoor units. Standard on all new Puron refrigerant fan coils and furnace coils.
4