This is a guide to the information needed to install a DEFINITY ONE Communications
System. For expanded information about these topics, see DEFINITY ONE Communications System Release 2.0 Installation and Upgrades
1.Install and cable the cabinet (same as ProLogix).
2.Power up the system (same as ProLogix).
3.Connect the laptop computer.
4.Access DEFINITY ONE via telnet and start a LAC bash session.
5.Verify the serial number (use serialnumber command). Ensure that the serial number matches the number on the TN795 faceplate.
6.Acquire a license file. License file information is available online. For further information, contact your Lucent technical services representative.
■
■
For external access: www.
For internal access: http://info.dr.lucent.com/~epr/contry
7.Request the RAS IP address from the INADS contact person.
8.Run setip to set the RAS IP address, the system name; and, if applicable, the customer LAN information.
9.Reboot the system, using the reboot nice command.
10.Wait for notification from INADS that the license file has been installed. This requires a reboot.
11.Administer the DEFINITY ONE platform. For example, set the system time and time zone, and enable customer logins. To enable AUDIX customer logins, execute the following commands from a Bash shell:
net user sa <new password>
net user sa /active
(Repeat these commands for vm and browse logins.)
12. Administer applications (DEFINITY, AUDIX, and AUDIX Networking).