FIELD REPLACEABLE UNIT DOCUMENTATION
TM
Satellite
3000 Series
14” DISPLAY MASK REMOVAL | FL INVERTER AND 14” LCD REMOVAL | |
|
|
|
Latch
Display
mask
LCD
Mask seals
1.Remove two rubber seals at the top corners of the display assembly and two mask seals at the bottom corners of the display assembly.
2.Remove four M2.5x5 silver screws securing the display mask.
3.There are 21 latches securing the display mask. Carefully insert your fingers between the display mask and the LCD module and pry open the latches starting from the bottom six latches, to the five latches on the right and left sides, ending with the top six latches.
LCD module
LCD/ | Tape |
FL cable | M2x4 brass screws FL cable |
FL inverter board |
1.Peel off the tape securing the FL cable.
2.Remove two M2.5x5 silver screw securing FL inverter board.
3.Carefully lift up the FL inverter board and disconnect the LCD/FL cable from CN1 and the FL cable
from CN2.
4.Remove two 2.5x6 black screws securing the LCD
top cover.
M2x3 silver screws
LCD/FL cable
5.Lay the top cover as shown above.
6.Peel off two capton tapes securing the LCD/FL cable and disconnect the cable.
7.Remove four M2x3 silver screws securing the LCD module to the LCD brackets and lift out the module.
NOTE: When you open and close the display assembly with the top cover off, hold it by the hinges to prevent the brackets from bending.
TOSHIBA
Tough Enough for Today’s World