Mustang Survival MD0450 manual Repacking, Your PFD p.13

Page 20

Repacking

IMPORTANT: Carefully read the entire Repacking instructions to achieve a properly packed Inflatable Vest with LIFTTM

If your Inflatable Vest with LIFTTM has been used and/or the hydrostatic inflator replaced, always inflate through the oral tube and check that it stays inflated at least overnight. With the dust cap in the top of the oral tube, gently squeeze the Inflatable Vest with LIFTTM until all air or gas has been expelled (Fig. 11). Do not wring or twist the Inflatable Vest with LIFTTM. Put the oral tube dust cap back in its stowed position on the oral tube (Fig. 22). Let the life jacket dry before packing.

1)Before repacking:

Completely deflate the Inflatable Vest with LIFTTM (see Deflation p. 11).

Remove the optional harness (MA1900), if equipped.

NOTE: Before following the repacking sequence, be sure to properly re-arm your Inflatable Vest with LIFTTM See Re-arming

Your PFD (p.13).

2)Ensure the oral-inflation dust cap is fitted in the stowed position (Fig. 22).

FIGURE 22

Dust cap

Dust cap

in stowed

position for

position

deflation

3)Open both front panel covers. Adjust the waist belt and chest belt buckles to their full lengths so that the Inflatable Vest with LIFTTM is laid out flat (Fig. 23 shows the right lobe, as worn).

17

MUSTANG SURVIVAL

Image 20
Contents Inflatable Vest With Lifttm Page Contents Approval Conditions and Carriage Requirements Conditions for Type V Approval in commercial applicationsPage What is AN Inflatable PFD? Instructions for USE Uninspected Commercial Vessel Use Component Inspection InstructionsReadiness Checklist When used with harness MA1900, the bottom of the belt mustIs, replace the inflator see Re-arming Your PFD, p Donning InstructionsMustang Survival Inflation Oral Inflation Fasten the chest straps and adjust to a snug fitAutomatic Backup Inflation In-water Adjustments Special Considerations for Automatic Devices Usage Below Freezing Open the tabsRe-arming Your PFD Dispose of the used inflator body TrashIndicator ShaftInlet ValveSealing ring Fig BlackRepacking Your PFD p.13Right Lobe Mustang Survival Page Tuck in the zipper tail, so it is not exposed Fig MA1900 Sailing Harness USE with MD0450 only Inserting the MA1900 Sailing Harness Page Mustang Survival Harness Closures Adjusting the MA1900 Sailing Harness Is Your PFD in Good and Serviceable CONDITION?Care and Maintenance Instructions Ii Ensure the manual pull-tab is accessibleCheck the following at the intervals listed below Before Each UseVi Ensure the single point status indicator is green Fig HOW and WHY to Test Your PFD Cleaning and StoringPut on the Inflatable Vest with Lifttm HOW do YOU Test Your PFD Using the Automatic INFLATOR?HOW do YOU Test Your PFD Using the Manual INFLATOR? HOW do YOU Test Your PFD Using the Oral INFLATOR? Wear Your PFD Hypothermia How hypothermia affects most adultsLessen heat loss and increase your survival time Additional Information Do not Attach PFD’S to Your BoatMustang Survival Page WE Save Lives for a Living