Lowrance electronic X-70A 3D manual 2D Zoom Manual Mode, Bottom Depth View

Page 20

matically disappear from the screen or press the CLR key to erase it.

2D ZOOM - Manual Mode

The zoom feature works the same in manual as it does in automatic with two exceptions. One, since the unit is in manual, the unit won’t change the range to keep the bottom signal on the display. Two, you can adjust the zoom “window” to any desired depth.

To zoom the screen in the manual mode, first press the ZOOM key. A screen similar to the one on the previous page appears. You’ll notice a new label on the screen: “ADJUST”. Press the key next to that label. A screen similar to the one at right appears.

The unit is now in the split- screen zoom mode. A zoom bar is on the far right side of the screen. Use the up and down arrow keys to move this bar up and down the right side of the screen. Everything be- tween the top and bottom of this bar shows on the left side of the screen in either 2X or

4X scale. When you have the zoom bar in the desired loca-

tion, press the CLR key to erase it or wait a few seconds and it will auto- matically disappear.

You can have the zoom bar stay on the screen continuously, by using the zoom bar menu. See the 2D Options in the MENUS section for more information.

BOTTOM DEPTH VIEW

To use the Bottom Depth View, first press the WINDOWS key. Now press the key next to the "384 Bottom" or "192 Bottom", depending on the trans- ducer you wish to use or have installed. Finally, press the CLR key. A screen similar to the one at the top of the next page appears.

This view shows the water depth in large digital numbers at the top left corner of the screen. If an optional speed/temperature sensor is installed, the unit can also show boat speed, distance travelled (log), surface water temperature, and a surface water temperature graph in this area.

Next to the digital display box is the chart record. This shows depth infor-

18

Image 20
Contents 70A 3D Table of Contents Specifications InstallationTransducer Installation IntroductionTransducer Location Transducer Assembly and Mounting Nut at this time Sonar Unit Mounting Power Connections Temp CableLowrance KeyboardDisplay General Modes of Operation Digital BOX Sensitivity OperationAutomatic 3D Zoom 3D Operation3D Range 2D Transducer Element Se 2D Operation3D Variview Page 2D Range Automatic modeLection Manual mode Upper and Lower Limits2D Zoom Automatic mode 2D Zoom Manual Mode Bottom Depth ViewFastrak Chart Stop AlarmsDepth Alarms MenusPage Zone Alarm Fish I.D Fish AlarmAlarm Mute Display Contrast Digital Sonar 2D View OptionsDigital BOX Options 2D Fastrak BAR Zoom BARDisplay Zone Alarm BAR Chart CursorMenu Grayline Chart Speed Back LightsSpeaker Volume Units of MeasureASP Advanced Signal Processing Menu Surface ClarityTemperature Graph Adjustment FishtrackReset Distance LOG Menu 3D Enhance3D Simulator Unit freezes, locks up, or operates erratically TroubleshootingUnit won’t turn on No fish arches when the Fish ID feature is off Noise Lowrance Electronics Full ONE-YEAR Warranty Lowrance ElectronicsLowrances UPS Return Service Authorization RA NumberAccessory Ordering Information Keep this LabelHow to Obtain Service How to Obtain Service U.S.A. Only