Insignia manual Using the 450TX

Page 24

USING THE 450TX

MENU FUNCTIONS

Display Speed. Display Speed controls the rate at which the graphic information

moves across the display. There are 5 possible speeds; the fastest rate (5) is the factory setting. If your boat is stationary or moving very slowly for extended periods, it may be desirable to update the display at

a slower rate. The closer the update rate matches boat speed, the more accurate is the graphic depiction of the terrain beneath your boat.

Use the UP and DOWN ARROWS to select the desired update rate. (1) is the slowest, (5) is the fastest. Use the MENU button to advance to the next menu.

The Display Speed setting is remembered when the unit is powered off.

Battery Alarm. The Battery Alarm Option allows you to select the voltage level at which the Battery Alarm activates.

At the Battery Alarm menu (under options), you will note that the default setting is OFF. Push the DOWN ARROW BUTTON to select the feature ON. Push the DOWN ARROW BUTTON again to move into the ADJUST BATTERY ALARM setting. Using the UP and DOWN ARROW BUTTONS, select a voltage between 9.0 and 12.0.

When the voltage drops below your selected voltage, an audible alarm will sound, and a battery alarm icon will be displayed on screen with current voltage level.

Bottom Black. There are two selections available: Off and On. The factory setting is Off. With this setting, the 450TX displays the bottom using 4 level grayscale. This allows you to determine the texture and relative hardness of the bottom. Selecting Bottom Black “ON” causes the unit to blacken in the display below the bottom.

22

Image 24
Contents Operations Manual Cal Table of Contents Installation Preparation AccessoriesInstallation Overview Parts SuppliedInstallation Overview Determining How to Mount the TransducerAlternate Transducers and Mounting Methods Alternate Transducers and Mounting MethodsPortable Mounting Trolling Motor MountingBeginning Installation Transducer ExchangeTransducer Exchange Using the 450TX HOW Sonar WorksHOW Sonar Works Simulator Operation Simulator OperationFeature Memory What YOU see ON-SCREENWhat You See On-Screen Installed Shows What YOU see on Screen Control Functions Control Functions 2d View Large Digit View Chart View Arrow Keys. The UP Arrow and Down Arrow make Menu Functions Menu FunctionsLow Sensitivity Using the 450TX Box will move vertically to remain in the general Using the 450TX Using the 450TX Voltages in excess of 20 or less Using the 450TX Bottom Black View ID+ On Raw Sonar Using the 450TX Speed offset is remembered after power is disconnected Advanced Features Using DiagnosticUsing the Diagnostic Feature Advanced Features Advanced Features Using Alternative Transducers Using Alternative TransducersWide side operation Advanced Features Maintenance Maintenance and TroubleshootingMaintenance TroubleshootingTroubleshooting Nothing happens when I turn the unit onThere is no transducer detected Unit comes on before I press POWER, and won’t turn off There is no bottom reading visible on the displayMy unit loses power at high speeds Get gaps in the reading at high speedsSpecifications TOP