Furuno IF-1500AIS manual Wiring, For IEC

Page 5

Wiring

Refer to the interconnection diagram at the back of this manual and the illustration below.

For IEC 61162-2

AIS

- External display

 

 

 

- Aux. display

 

 

 

- Pilot plug

WHT

 

RD A

 

 

 

 

 

BLK

 

 

 

 

 

RD B

 

 

 

 

 

YEL

 

 

 

 

 

TD A

 

 

 

 

 

GRN

 

 

 

 

 

TD B

 

 

 

 

 

RED

 

 

 

 

 

ISO GND

 

 

 

 

 

BLU

 

 

 

 

 

ISO GND

 

 

 

 

 

 

 

 

 

 

 

 

MJ-A7SPF0003-050

 

 

 

 

 

 

 

 

 

F.G.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

IF-1500AIS J1:AIS IN

1TD A

2TD B

3RD H

4RD C

5SIG. GND

6SIG. GND

7F.G.

Notice:

Do not connect "SIG. GND" of the IF-1500AIS to "Frame Ground".

For IEC 61162-1, NMEA-0183

AIS

- External display

 

 

 

 

- Aux. display

 

 

 

 

- Pilot plug

WHT

 

RD H

 

 

 

 

 

BLK

 

 

 

 

 

 

 

RD C

 

 

 

 

 

YEL

 

 

 

 

 

 

 

TD A

 

 

 

 

 

 

 

GRN

 

 

 

 

 

 

 

TD B

 

 

 

 

 

RED

 

N.C

 

 

 

 

 

BLU

 

N.C

 

 

 

 

 

MJ-A7SPF0003-050

 

 

 

 

 

 

 

 

 

 

 

 

 

F.G.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

IF-1500AIS J1:AIS IN

1TD A

2TD B

3RD H

4RD C

5SIG. GND

6SIG. GND

7F.G.

Notice:

Do not connect "SIG. GND" of the IF-1500AIS to "Frame Ground".

4