Schumacher PI-200 owner manual Specifications, Replacement Parts, Before Returning for Repairs

Page 10

10. SPECIFICATIONS

 

 

Maximum Continuous Power

200 Watts

Surge Capability (Peak Power)

400 Watts

No Load Current Draw

<0.3A

Wave Form

Modified Sine Wave

Input Voltage Range

10.5V – 15.5V

DC

Output Voltage Range

120V ± 5% AC

Low Battery Alarm

Audible, 11V ± 0.3V

DC

Low Battery Shutdown

10.5V ± 0.3V

DC

High Battery Shutdown

15.5V ± 0.5V

DC

Optimum Efficiency

85%

AC Outlet

One, NEMA 5 - 15 USA

USB Port

One, 5V DC

Fuse

One, 25A (Spade Type)

Dimensions

6.5" L x 3.38" W x 2.2" H

Weight

approximately 1.6 lbs.

11.REPLACEMENT PARTS

Fuses – Replacement fuses can be purchased at most electronic component retailers.

12.BEFORE RETURNING FOR REPAIRS

When an UNKNOWN OPERATING PROBLEM arises, please read the complete manual and call the customer service number for information. This will usually eliminate the need for return.

If the above solutions do not eliminate the problem,

or for information about troubleshooting or replacement parts,

call toll-free from anywhere in the U.S.A.

1-800-621-5485

7:00 am to 5:00 pm Central Time, Monday through Friday

For REPAIR OR RETURN, contact Customer Service at

1-800-621-5485. DO NOT SHIP UNIT until you receive a RETURN MERCHANDISE AUTHORIZATION (RMA) number from Customer Service at Schumacher Electric Corporation.

• 10 •

Image 10
Contents Inversor de Energía Manual DEL UsuarioImportant Safety Instructions Save These Instructions Risk of Electric Shock or FireBefore Using Your Power Inverter Page Connecting Inverter Cables Fastening the Inverter to a Flat SurfaceUsing the USB Port Operating InstructionsPower Source LED Indicator and Shutdown Protection If the Inverter Fuse BlowsTroubleshooting Problem Reason Solution ShutdownReplacement Parts SpecificationsBefore Returning for Repairs Page Do not Return this Product to the Store Do not Send Unit to this Address for Repair No Envíe LA Unidad a Esta Dirección Para SU Reparación Page EL Riesgo DE Descarga Eléctrica Incendio Antes DE Usar SU Inversor DE Energía Page Para Conectar LOS Cables DEL Inversor Para Sujetar EL Inversor a UNA Superficie PlanaInstrucciones DE Operación El uso de Puerto USB Fuente DE Energía Indicador LED Y Protección DE DE Apagado SI SE Quema EL Fusible DEL Inversor Resolución DE Problemas Causa Posible Solución CierreProblema Causa Posible Solución EspecificacionesPiezas DE Repuesto Teléfono Correo Electrónico services@schumacherelectric.com