Harbor Freight Tools 69662 Functions, Operation Maintenance, 12 V / 400 Ah Battery Bank Example

Page 7

Locate battery bank in a clean, well- ventilated area, away from ignition sources and flammable materials. Batteries release explosive hydrogen gas while charging.

Charge, store, and maintain batteries according to supplier’s instructions.

(To Negative

Inverter Terminal)

OUTPUT

12 V /

200* Ah

Lead- Acid + Battery

To Increase

Capacity, Connect

Additional

12 V / 200* Ah +

Lead-Acid

Batteries Here

12 V /

200* Ah

Lead- Acid + Battery

OUTPUT

(To Positive

Inverter Terminal)

c.Then connect all the negative terminals to one another.

d.Connect the negative and positive output cables to opposite ends of the bank. Do not allow the output cables to touch one another.

e.Test the voltages at the output cables to help ensure that the battery bank is properly wired. If the voltage is higher than 13 volts, then part of the battery bank is likely connected in series (a negative terminal of one battery attached to a positive terminal of another) instead of in parallel. Carefully examine the diagram and correct the wiring before attaching to the inverter.

6.Turn the inverter’s Switch off.

7.Connect the output cables from the battery bank to the inverter.

Safety

Setup

12 V / 400^ Ah Battery Bank Example

* 200 Ah batteries shown for illustration.

^Bank Capacity = (single battery capacity) x (# of batteries) 400 Ah capacity is for two, 200 Ah batteries.

b.Connect the batteries in parallel as shown above. Connect all of the positive terminals to one another.

Functions

FRONT

Power

Power

BACK

Level

Switch

Indicator

 

 

USB

Connection

115 VAC Outlets

Ground Connection

Negative (-) Cable

Positive (+) Cable

Connection

Connection

 

Figure A

Item 69662

For technical questions, please call 1-800-444-3353.

Page 7

Operation

Maintenance

Image 7
Contents Page General Precautions Table of ContentsInstallation Precautions Maintenance Battery PrecautionsOperation Precautions Safety SetupFet Sa Service PrecautionsSymbology Do not open housing. Contains no user-serviceable partsModified Sine Wave Setup Operation MaintenanceSpecifications Output WaveformInstallation Setup No rati Ope MaintenanFor technical questions, please call 12 V / 400 Ah Battery Bank Example Operation MaintenanceFunctions Operating Instructions Tool Set UpTypical Appliance Power Consumption Setup No ratiDo not open housing Cleaning, Maintenance, and LubricationSafety Maintenance and ServicingFet Sa Setup No rati Ope Maintenan TroubleshootingProblem Possible Causes Probable Solutions Qty Parts List and DiagramPart Description Qty Part DescriptionMission Oaks Blvd. PO Box 6009 Camarillo, CA 93011 800 Limited 90 Day Warranty