Feature Identification
Identify the premium features on your specific model and quickly locate instructions on how to maximize their use.
1Operating Mode Switch: controls Inverter operation. Set this
2“LOAD” Indicator Lights: intuitive “traffic light” signals show approximate equipment load level. See "Operation for instructions on reading indicator lights.
3“BATTERY” Indicator Lights: intuitive “traffic light” signals show approximate charge level of your battery. See "Operation" for instructions on reading indicator lights.
4DC Power Terminals: connect to your battery terminals. See "Battery Connection" for connection instructions.
5Ground Fault Interrupter (GFCI) AC Receptacles: allow you to connect equipment that would normally be plugged into a utility outlet. Enhancing safety, they feature ground fault interrupter circuits that trip if there is a mismatch between the line current and the neutral current.
6Resettable Circuit Breaker(s): protect your Inverter against damage due to overload. PV3000GFCI model includes two separate
7Remote Control Module Connector: allows remote monitoring and control with an optional module (Tripp Lite model APSRM4, sold separately or included with PV3000GFCI model). See remote module owner’s manual for connection instructions.
8Battery Charge Conserver (Load Sense) Dial: conserves battery power by setting the
9
10Main Ground Lug: properly grounds the Inverter to vehicle grounding system or earth ground. See "Battery Connection" for connection instructions.
Low Battery Alarm/Shutdown (internal, not shown): automatically detects low voltage and shuts down Inverter to preserve vehicle battery.
Overload Alarm/Shutdown (internal, not shown): automatically detects wattage overload on Inverter outlets and shuts down Inverter as a protective measure.
|
|
|
|
|
|
|
| 1 | 8 | 3 | 7 | 2 |
| 12V DC | CAUTION! will blow internal fuses. See manual. |
|
|
|
|
|
|
|
|
| |
|
|
| Observe proper polarity. Reversed polarity |
|
|
|
|
|
|
|
|
|
PV1800GFCI Rear Panel | 4 | 9 | 4 | PV1800GFCI Front Panel |
|
|
|
|
| 5 |
| 10 |
9 | 4 |
| 9 | 5 | 8 | 3 | 7 | 2 | 1 |
|
| 5 |
| CAUTION! will blow internal fuses. See manual. |
|
| SENSE | BATTERY |
| LOAD |
|
|
|
| |
| Observe proper polarity. Reversed polarity |
|
| LOAD |
|
|
|
|
|
12V DC | GREATER | LESSER | HI | REMOTE | LOW |
|
|
|
| LOAD | LOAD | MED | MED | REMOTE | OFF | ON | |
| ON | ON | LOW |
| HI |
|
|
|
|
|
|
|
|
| 10 | ||
|
|
|
|
|
|
|
| |
|
| OUTPUT |
|
|
|
| OUTPUT | |
|
| CIRCUIT |
|
|
|
| CIRCUIT | |
|
| BREAKER |
|
|
|
| BREAKER | |
|
| 20A |
|
|
|
|
| 20A |
PV3000GFCI Rear Panel
PV3000GFCI Front Panel
6
3