Operation
•Turning off the RG Battery Backup
Turn switch to OFF position. The “ON A/C” LED light should turn off.
•To Silence Audible Alarm
Turn mute switch to ON (down) position.
•To Conduct a Self-Test
Use the self-test to verify both the operation of the RG Battery Backup and the condition of the battery. Turn the mute switch ON then OFF, then ON and OFF again within five seconds. During the self-test, the RG Battery Backup operates in backup mode.
The RG Battery Backup automatically conducts a self-test every 21 days.
NOTE: During the self-test, the RG Battery Backup briefly operates on battery-backup power. The “Testing Battery” LED will flash for five minutes during the test period. If the RG Battery Backup passes the self- test, it returns to online operation. If the RG Battery Backup fails the self- test, it immediately returns to online operation and lights the “Replace Battery” LED. The loads are not affected. Recharge the battery overnight and perform the self-test again. If the “Replace Battery” LED is still on, the battery needs to be replaced.