TROUBLESHOOTING
If symptoms of poor performance develop, the following chart can be used as a guide to correct the problem.
When diagnosing faults in operation of the tool, always make sure the hydraulic power source is supplying the cor- rect hydraulic flow and pressure as listed in the table. Use a flowmeter known to be accurate. Check the flow with the hydraulic fluid temperature at least 80 °F/27 °C.
| SYMPTOM | CAUSE | SOLUTION |
| Tool does not run. | Power unit not functioning. | Check power unit for proper flow |
|
|
| and pressure |
|
|
| |
|
| Couplers or hoses blocked. | Remove restriction. |
|
| Pressure and return line hoses | Be sure hoses are connected to their |
|
| reversed at ports. | proper ports. |
|
| Mechanical failure. | Have inspected and repaired by an |
|
|
| authorized Stanley dealer. |
|
| Check hydraulic system for excessive | |
|
|
| |
|
|
| bar measure at the end of the tool |
|
|
| operating hose. |
| Tool does not compact effectively. | Power unit not functioning. | Check power unit for proper flow |
|
|
| and pressure |
|
|
| |
|
| Couplers or hoses blocked. | Remove restriction. |
|
| Check hydraulic system for excessive | |
|
|
| |
|
|
| bar measure at the end of the tool |
|
|
| operating hose. |
|
| Fluid too hot (above 140 °F/60 °C) | Provide cooler to maintain proper oil |
|
| Fluid too cold (below | temperature. Bypass cooler to warm |
|
| 60 °F/15.5 °C) | up oil or provide cooler to maintain |
|
|
| proper temperature. |
|
| Tamper shoe too large for soil | Use smaller shoe for |
|
| conditions. | operations (P/N 01849). |
| Tool operates slow. | Low oil flow from power unit. | Check power source for proper flow. |
|
| High | Check hydraulic system for excessive |
|
|
| |
|
| Couplers or hoses blocked. | Remove restrictions. |
|
| Fluid too hot (above 140 °F/60 °C) | Provide cooler to maintain proper oil |
|
| Fluid too cold (below | temperature. Bypass cooler to warm |
|
| 60 °F/15.5 °C) | up oil or provide cooler to maintain |
|
|
| proper temperature. |
| Tamper gets hot. | Hot oil going through tool. | Check power unit. Be sure flow rate is |
|
|
| not too high causing excess oil to go |
|
|
| through the relief valve. Provide cooler |
|
|
| to maintain proper oil temperature. |
|
|
| Bypass cooler to warm up oil or |
|
|
| provide cooler to maintain proper |
|
|
| temperature |
|
|
| Eliminate flow control devices. Do not |
|
|
| exceed recommended flow. |
12 ► TA54 User Manual |
|
|