7 Troubleshooting

PROBLEM: AC product will not operate, no inverter lights are ON.

Possible cause

Remedy

 

 

Battery is defective.

Check battery and replace if

 

required.

 

 

Loose connections.

Check connections.

Fuse is blown.

Replace fuse (see page 20).

 

 

PROBLEM: Measured inverter output is too low.

Possible cause

Remedy

 

 

Standard “average-

Inverter’s “modified sine

reading” AC voltmeter

wave” output requires “true

used to measure output

RMS” voltmeter for accurate

voltage, resulting in an

measurements.

apparent reading 5 to 15 V

 

too low.

 

 

 

Battery voltage is too low.

Recharge battery.

 

 

18

Image 23
Contents XPower Pocket Inverter About Xantrex Date and Revision Contents Specifications Introduction Page Important Safety Information Page Page Page Additional Safety Guidelines Safety Features Features and Accessories Inverter FeaturesUsing the DC Cable with Cigarette Lighter Plug Using the InverterConnecting the Adapter and DC Cable Using the DC Cable with Airplane Power Plug Airline Compatibility Operating Guidelines Inverter OperationPage Interference with Electronic Equipment Battery Operating TimeBuzzing sound in audio systems and radios Possible cause Remedy TroubleshootingProblem AC product will not operate, red Fault light on Replacing the Fuse USB Power Output H8 SpecificationsAC Power Output Physical Specifications DC Power SpecificationsWarranty Warranty and ReturnPage Page Page Product DisclaimerExclusions Page Return Material Authorization Policy Return Procedure Out of Warranty Service