Emerson Process Management 51000 instruction manual Contents, Introduction, Scope of Manual

Page 1

Instruction

51.LF:IM

Baumann51000 Series Instructions

April 2007

Baumann51000 Series Low Flow

Control Valve Instructions

CONTENTS

 

Introduction

1

Scope

1

Safety Precautions

1

Maintenance

2

Installation

3

Actuator Removal

3

Plug and Packing Replacement

3

Disassembly of Valve

3

Reassembly of Valve

3

Body Assembly Part Numbers

4

Type 16 Actuator Part Numbers

6

DimensionsandWeights

7,8

INTRODUCTION

The Baumann 51000 series control valve is optimally designed for demanding low flow control and is a perfect fit where space is at a premium. This compact package provides the connection integrity of flanged body globe valves while being significantly lighter and easier to install.

SCOPE OF MANUAL

This instruction manual includes installation, maintenance, and parts information for the 51000 series control valve and type 16 actuator.

No person may install operate or maintain a 51000 series control valve without first being fully trained and qualified in valve, actuator and accessory installation, operation and maintenance, and carefully reading and understanding the contents of this manual. If you have any questions about these instructions contact your Fisher® sales office before proceeding.

NOTE

Neither Emerson®, Emerson Process Management, Fisher®, nor any of their affiliated entities assumes responsibility for the selection, use and maintenance of any product. Responsibility for the selection, use and maintenance of any product remains with the purchaser and end- user.

:$51,1*

Always wear protective gloves, clothing, and eye wear when performing any installation operations to avoid personal injury.

Personal injury or property damage caused by sudden release of pressure or bursting of pressure retaining parts may result if service conditions exceed those for which the product was intended. To avoid injury or damage, provide relief valve for over pressure protection as required by government or accepted industry codes and good engineering practices.

Check with your process or safety engineer for any additional measures that must be taken to protect against process media.

If installing into an existing application, also refer to the WARNING at the beginning of the Maintenance section in this instruction manual.

:$51,1*

This valve is intended for a specific range of pressures, temperatures and other application specifications. Applying different pressures and temperatures to the valve could result in parts damage, malfunction of the control valve or loss of control of the process. Do not expose this product to service conditions or variables other than those for which the product was intended. If you are not sure what these conditions are you should contact your Fisher sales office for more complete specifications. Provide the product serial numbers (shown on the nameplate) and all other pertinent information.

1

Image 1
Contents Introduction ContentsScope of Manual Baumann 51000 Series Instructions MaintenancePlug and Packing Replacement Refer to Figures 1 InstallationValve Reassembly For Air-to-Close This is not requiredDescription QTY Part Number Body Assembly Part Numbers25 SS N10276 Follower PointPlug Selection Valve SizeType 16 Actuator Part Numbers Ring Packing KITKEY Part Number QTY Description KEY QTY Description Part NumberValve Size Material Approximate Weights Dimensions and WEIGHTS, Body SubassemblyInch Lbs Actuator Instrument Approximate Weight Type WEIGHTS, Actuator and Instruments only