| Troubleshooting | |
Troubleshooting |
| ||
|
|
| |
Problem | Cause | Solution | |
|
|
| |
|
|
| |
Transceiver will not com- | Incorrect COM port selected for trans- | Ensure correct COM port is selected. | |
municate to meters and | ceiver. |
| |
TLMs |
|
| |
Communication (serial) cable is not | Verify that communication cable con- | ||
| |||
| connected between the transceiver and | nects transceiver to PC correctly. See | |
| PC. | page 6. | |
|
|
| |
| Transceiver is not powered up. | Verify transceiver is powered up. | |
|
|
| |
| You attempted to communicate while | Wait for red lights on transceiver to go | |
| red lights on transceiver were on. | blank before attempting to communi- | |
|
| cate. | |
|
|
| |
| Transceiver dipswitches are not set for | Verify transceiver dipswitches are set | |
| correct communication (serial) cable. | for appropriate communication (serial) | |
|
| cable. See pages 10 and 11. | |
|
|
| |
| Transceiver is out of RF range of | Ensure transceiver is located within RF | |
| meters or TLMs. | range of meters and TLMs. | |
|
|
| |
Transceiver communi- | Transceiver is out of RF range of | Ensure transceiver is located within RF | |
cates intermittently to | meters or TLMs. | range of meters and TLMs. | |
some meters and TLMs. |
|
| |
Two meters or TLMs are programmed | Verify that each meter and TLM is cor- | ||
| |||
| to the same address. | rectly programmed to a unique | |
|
| address. | |
|
|
|
309498H | 15 |