Installation
Installation
It is required to remove the power supply before install- ing the alternator conversion kit. Always have a qualified electrician perform wiring connections.
Remove Power Supply
1.Shutdown XM
2.Disconnect incoming power cable connections to power supply (E) and ground lead (X) from junction box (JB).
D
JB
G
E
X
F
r_256991_313293_3
FIG. 2: Remove Power Supply
3.Disconnect power supply cable (G) from fluid control module (D).
4.Disconnect power cable from power filter (F) and from terminal blocks in junction box (not shown).
5.Loosen mounting screws and remove power supply
(E) and filter (F) from control box (CB).
6.Disconnect CAN cable (H) from USB front CAN con- nector and display module (C). See FIG. 1 on page 3.
NOTE:
Cable (H) will not be used for alternator conversion kit.
7.Disconnect CAN cable (J) from USB module and fluid control module. Do not discard cable (J). CAN cable (J) will be used by alternator conversion kit.
NOTE:
Keep power supply (E) and filter (F) connected so that you can easily reinstall your power supply.
4 | 313293C |