Graco 256991 important safety instructions Installation, Remove Power Supply

Page 4

Installation

Installation

It is required to remove the power supply before install- ing the alternator conversion kit. Always have a qualified electrician perform wiring connections.

Remove Power Supply

1.Shutdown XM plural-component sprayer. See oper- ation manual 312359 for shutdown procedure.

2.Disconnect incoming power cable connections to power supply (E) and ground lead (X) from junction box (JB).

D

JB

G

E

X

F

r_256991_313293_3

FIG. 2: Remove Power Supply

3.Disconnect power supply cable (G) from fluid control module (D).

4.Disconnect power cable from power filter (F) and from terminal blocks in junction box (not shown).

5.Loosen mounting screws and remove power supply

(E) and filter (F) from control box (CB).

6.Disconnect CAN cable (H) from USB front CAN con- nector and display module (C). See FIG. 1 on page 3.

NOTE:

Cable (H) will not be used for alternator conversion kit.

7.Disconnect CAN cable (J) from USB module and fluid control module. Do not discard cable (J). CAN cable (J) will be used by alternator conversion kit.

NOTE:

Keep power supply (E) and filter (F) connected so that you can easily reinstall your power supply.

4

313293C

Image 4
Contents Alternator Conversion Kit Contents Related ManualsComponent Identification Power Supply Cable ConnectionsKey Installation Remove Power SupplyInstall Alternator Install Regulator AssemblySetup Connect HoseConnect Cables Set Air RegulatorParts Part Description QtyTechnical Data Technical Data 313293C Graco Standard Warranty Graco Information