Graco 309524N Cable Clamp Kit 246303 Installation, Cable Clamp Kit Key

Page 27

Accessories

Cable Clamp Kit 246303 Installation

1.Slide cable clamp (3) onto cable (2).

2.Place washer (F) on fitting (E).

3.Push conical-shaped packing (D) into fitting (E).

4.Place washer (C) on retaining nut (B).

Ref.

 

 

No.

Part No. Description

Qty

2

Cable, 16.4 ft. (5 m), 221° F

1

 

(105° C)

 

3

113162 Clamp

1

5.Screw retaining nut (B) into fitting (E). Tighten with no more than 2 in. (50 mm) stripped black and blue wires and 4 in. (100 mm) yellow/green ground wire inside terminal junction box.

6.Place one side of retaining clip onto retaining clip nut, and insert as shown.

3

2

05544

FIG. 19: Cable Clamp Kit

Key:

ARetaining clip

BRetaining nut

CWasher

D Packing

EFitting

FWasher

F

E

D

C

B

A

05554

FIG. 20: Kit Assembly

309524N

27

Image 27
Contents Hazardous Location Heater shown Viscon HPApprovals ModelsHazardous Location Heaters Non-hazardous Location HeatersContents TranslationsManual Conventions Skin Injection Hazard Equipment Misuse Hazard Installation Typical Installation DrawingKey Selecting Tubing Chart NotesMounting Heater Wall MountingBracket Cart Mounting Fluid Connections AccessoriesRequirements For All Installations Hazardous Location Installation RequirementsElectrical Connections Wall Mounted Wiring Cart Mounted WiringGrounding To find your fluid’s Under-Boil temperature Determining Proper Fluid TemperatureEffect of Temperature on Viscosity Priming System Pressure Relief ProcedureOperation Initial FlushingSetting Heater Control Adjusting for SprayingRefer to FIG Unclogging Fluid Passages MaintenanceFollow Pressure Relief Procedure, FlushingProblem Cause Solution TroubleshootingPrimary Thermostat & Probe Backup ThermostatReassembly Notes RepairThermostat Repair Hazardous Location Heaters Thermal Limit Sensor Control KnobHeater Block Control Repair Hazardous Location Heaters Hazardous Location Heaters PartsPart No. Description Qty Ref. No Heater Block Series Volts / WattsNon-Hazardous Location Heaters Enclosure Accessories Cable Clamp Kit Key Cable Clamp Kit 246303 InstallationMaximum Temperature Rise vs. Flow Rate Technical DataDimensions For Graco Canada Customers Graco Standard Warranty