Installation
Mounting the Pump
Models 226013, 226018, 244637
1. Mount the pump support bracket (86). (FIG. 4)
86
FIG. 4
2.Remove inductor plate nut (11 or 24), locking ring (8 or 23) and
3.In order, slide inductor plate nut (11 or 24), locking ring (8 or 23) and
4.Adjust the inductor plate on the pump so that the pump intake is 0.12 in. (3.2 mm) above the mount- ing base.
5.Tighten the lock nut (11 or 24) securely. Continue with Step 4 below.
| DETAIL | pump riser |
8 or 23 |
| |
| tube | |
|
| 11 or 24 |
2 or 22 | pump intake |
| slots |
| 0.12” (3.2 mm) |
FIG. 5
NOTE: The full length of the pump intake slots must be just below the bottom of the inductor cone.
Model 204490
Refer to FIG. 6 for Steps 1-3 below.
1.Lubricate the
2.Mount the pump on the pump support (64) so the fluid outlet faces front.
3.Guide the pump intake valve as far as possible into the inductor plate, then tighten the set screws (19). Continue with Step 4 below.
18 | 20 | 19 |
| ||
|
|
FIG. 6
306556S | 7 |