Attwood 5095 installation instructions Volt 1-Mile Bi-Color Pole Light with Task Light

Page 1

®

3

12-Volt 1-Mile Bi-Color Pole Light with Task Light

5095

Installation Instructions

Attwood marine hardware, navigational lighting, bilge pumps, and other marine accessories are specified more than any other brand by America’s best-known boat manufacturers as original equipment. Look to Attwood for quality replacement parts and marine accessories.

SAVE THESE INSTRUCTIONS

 

Form Number 69383 Rev. B

03-10

FEATURES

The Attwood 12-Volt, 1-Mile Navigation Combination Lights for boats up to 39.6 ft. (12 meters) incorporate a separately switched Task Light. They feature impact resistant, UV-stable polycarbonate housings.

Certification: Bi-Color, 12-Volt, Sidelight with Tasklight.

Meets USCG CFR 183.810, ABYC A-16 requirements, and all applicable standards as tested by Imanna Labs on 1/13/2003. 1 Nautical Mile visibility. Uses 9235 #906 Lamp, 13V, 6 Candle Power.

REQUIRED FOR INSTALLATION

Cordless drill with 1/8" (3mm), 3/8" (10mm) and 3/4" (19mm) bits.

Screwdriver.

Three #8 or #10 stainless pan head screws per light.

Non-silicone sealant.

WARNING:

To prevent personal injury, always disconnect the power source when installing or servicing this product. Always remove the boat from the water before using 120V AC power tools.

LOCATION

Lights must be mounted to an unobstructed smooth surface on the gunwale, deck or superstructure. Locate Bi-Color Combination Light in an area as far forward as possible. (Figure 1)

STANDARD 3-PIN BASE WIRING CONFIGURATION

For proper operation, the base that will accept the pole light must be wired as in Figure 2.

POLE LIGHT INSTALLATION

CAUTION:

All positive (+12V DC) wires must be fused to protect your circuits and vessel. The Combination Light requires a 1-amp fuse. The Task Light requires a 1-amp fuse and separate wire circuit. The aluminum pole of the Universal Fit Light is not connected to an electrical ground. (Figure 2)

1.Insert pole into base, aligning screw with slot in base.

2.Press down firmly to engage electrical connectors.

3.Slide locking collar down to base, rotate until lower ring can be inserted inside top of base.

4.Press down into base and rotate until locking collar tightens between pole and base.

NOTE:

Periodically check pole to make sure it is secure.

5.To remove light, rotate locking collar in opposite direction until it loosens, then pull up on pole. (Figure 3)

After installation, activate lights to verify proper operation. Navigation light regulations require lights to be operated with a three-position switch that provides for:

Running lights (combination light and all-round light).

Anchor lights (all-round light only).

Off.

Check the Task Light by pressing on switch at rear of light to turn Task Light on. (Figure 4)

Figure 3

Figure 1

Figure 2

Red Green

To +12-Volt

Navigation

Light Switch

Locking Collar

Lower Ring

Screw

White

To +12-Volt

To -12-Volt

 

Circuit with Fuse

 

Battery

 

(Powered Constantly)

 

 

Image 1