6.Connect the power cord at the back of the instrument to a 12 V power supply which is active whenever the ignition switch is on.

The red lead should be connected to the positive terminal of the power supply via a 1 amp fuse or a 1 amp circuit breaker. The black lead should be connected to the negative terminal.

7.Obtain the power from a 12 V source as directly as possible. Avoid power circuits which share loads with ignition, alternators, radio transmitters, etc. Excessive electrical noise associated with such devices may prevent the instrument from operating properly.

8.Connect the RCA phono plug on the transducer cable to the instrument.

Instrument

 

Panel

 

2-Inch

Mounting Nut

Hole

 

 

Mounting

 

Bracket

Instrument

 

Sealing

 

Gasket

 

Figure 2. Depth Sounder Installation

FACE PLATE

INSTRUMENT

PANEL WALL

MOUNTING

NUT

MOUNTING

BRACKET

DEPTH SOUNDER

BODY

Figure 3. Side View of Mounted Depth Sounder

10DS41 Owner’s Manual

Image 11
Contents Dual Station Operation Contents Specifications Operation AlarmsAlarms On/Off Shallow AlarmKeel/Surface Offset Instrument SetupDeep Alarm Units of Measure Transducer SettingTroubleshooting Options What comes with your Digital Depth SounderStandard DTS55 Replacement PartsInstrument Installation InstallationFace Plate Installation Bracket MountingGeneral Transducer InstallationSailboat Transducer In-Hull Installation Master/Slave Selection Appendix a Dual Station OperationLinked or Separate Selection As Nmea repeater Appendix B Nmea Repeater Mode