Standard Horizon DS41 owner manual Linked or Separate Selection

Page 16

Linked or Separate Selection

By default a dual station pair of DS41 instruments automatically keep the following settings the same in both instruments:

Alarms On/Off

Alarm Values (Deep and Shallow)

Keel Offset (see note)

Units of measure (see note)

Example: Switching an alarm off on the slave instrument will also switch the alarm off on the master instrument. The reverse also applies, alarms changed on the master will be automatically changed in the slave instrument.

Note: The keel offset and units of measure should only be changed on the Master instrument.

If independant settings are required the link feature can be disabled.

To enable or disable the linked mode:

1. Apply power while holding down the # key.

￿OFF

Hold down during power up

2.When the unit is on. The display will first indicate the current display unit:

￿￿￿ Example

3.Continue to hold the # key. The display will indicate the current master/slave selection.

Slave

4.Continue to hold the # key until the display indicates the current linked/ separate selection.

Linked

Separate

5.Use the " and # keys to change the selection.

6.To exit this mode, press and hold both the " and # keys simultaneously. Alternatively, if no keys are pressed for a period of 5 seconds normal depth display will commence.

ON￿ ￿OFF

Press simultaneously

Note:

This setup procedure applies to

the master device and all slave devices.

For separate operation all devices, including the master, must be set to Separate mode. Also, for linked operation all devices, including the master, must be set to Linked mode.

DS41 Owner’s Manual15

Image 16
Contents Dual Station Operation Contents Specifications Alarms Alarms On/OffShallow Alarm OperationDeep Alarm Instrument SetupKeel/Surface Offset Transducer Setting Units of MeasureTroubleshooting Standard What comes with your Digital Depth SounderOptions Replacement Parts DTS55Face Plate Installation InstallationInstrument Installation Mounting BracketTransducer Installation GeneralSailboat Transducer In-Hull Installation Appendix a Dual Station Operation Master/Slave SelectionLinked or Separate Selection Appendix B Nmea Repeater Mode As Nmea repeater