stalling an inline switch. This will let you shut off power to the power cable when the unit is not in use. When you are not using the unit, you should always shut off power to the power cable, es- pecially when the power cable is disconnected from the unit.

To unit

Red wire with

3 amp fuse

 

Black wire

12 volt battery

Power connections for the Cuda 242 sonar unit

(direct battery connection shown).

If possible, keep the power cable away from other boat wiring, espe- cially the engine's wires. This will provide the best isolation from elec- trical noise. The power cable has two wires, red and black. Red is the positive lead, black is negative or ground. Make sure to attach the in- line fuse holder to the red lead as close to the power source as possible.

For example, if you have to extend the power cable to the battery or power buss, attach one end of the fuse holder directly to the battery or power buss. This will protect both the unit and the power cable in the event of a short. It uses a 3-amp fuse.

Caution:

Do not use this product without a 3-amp fuse wired into the power cable! Failure to use a 3-amp fuse will void your war- ranty.

24

Image 28
Contents Cuda 242 Portable Copyright 2006 LEI-Eagle All rights reserved Table of Contents Troubleshooting Capabilities and Specifications Cuda 242 & Cuda Portable GeneralBack-up memory SonarSonar sounding Automatic rangingHow Sonar Works Installation PreparationsRecommended Tools and supplies Selecting a Transducer Location How low should you go? Shoot-Thru-Hull vs. Transom Mounting Transom Transducer Assembly and Mounting Align plastic ratchets in bracket Insert bolt and check transducer position on transom Transom Page Bottom Hull Flat-bottom hullDeep-vee hull Attach motor mounting bracket to transducer Transducer Orientation and Fish Arches Transducer angles and their effects on fish arches Shoot-Thru-Hull Preparation Testing Determines Best Location Second bottom True bottom Manual range setting Shoot-Thru-Hull Installation Epoxy transducer to hull Power Connections permanent mount only To unit Red wire with Amp fuse Black wire Volt battery Page 107.5 82.7 156 Page Portable Sonar Installation Installing the Batteries Mounting the Unit Page Tie Nylon Cord here Suction Portable Transducer Storage Page Operation Keyboard BasicsMenus MemoryUP & Down Arrows ↑ ↓ Display Full Chart Depth Range Zoom Zoom Range menu with the 40-80 foot zoom selected To adjust sensitivity in Manual Mode To adjust sensitivity in Auto ModeSensitivity Grayline Grayline control bar Chart Speed Chart Speed control bar Fish I.D. FishTrack Alarms Fish AlarmDepth Alarms Shallow AlarmDeep Alarm Battery Alarm Noise Reject and ASP Depth Display Temperature DisplayTo display Depth To display Temperature Voltage To display battery voltageUnits Backlight ContrastSimulator Set LanguageSoftware Information To select a languageReset Options Unit wont turn on Unit turns on only in simulator modeUnit freezes, locks up, or operates erratically Page No fish arches when the Fish I.D. feature is off NoisePage Eagle Electronics How to Obtain Service… Not toll-freeAccessory Ordering Information for all countries Visit our web site