ACR Electronics AIS-300 Maintenance Appendix a Serial Data Interface, Power/ Data connection

Page 22

TX timeout

This is a yellow LED which indicates when lit that the CSTDMA transmitter is prevented from transmitting. Reasons for this include the following:

The transponder‟s internal GPS receiver is not yet ready. The yellow LED will go out and the green LED will light when GPS receiver is ready.

The transponder was unable to transmit an AIS message due to the channel being already occupied, e.g. by transmissions from other AIS transponders. Wait 10 minutes and verify GPS antenna connection.

The transponder‟s internal GPS receiver is not operating. Contact your local dealer for service.

Error

This is a red LED which indicates, when lit, one of the following status conditions is possible: Transmitter lockout timer (1 second maximum) has operated

GPS is unable to gain lock after 30 minutes VHF antenna VSWR is out of range Power Supply is out of range

Background noise level is above the threshold level (-77dBm) MMSI is not entered

Blue LED

The unit has a blue LED that, when lit, indicates one of the following two conditions depending on how it is programmed:

Safety Related Message (SRM) status

The Safety Related Message (SRM) button (not included, recommend momentary contact switch rated for > 25mA) has been depressed for more than 2 seconds and the pre-set SRM has been sent. If the SRM LED is illuminated it is not possible to send another SRM. An SRM can be sent once a minute. The payload within the message 14 transmission is the text string “MAYDAY MAYDAY”.

Silent Mode Function (if user configures SRM switch to act as Silent Mode switch)

This indicates that the Silent Mode button has been depressed for more than 2 seconds and the pre-set Silent Mode has been activated. If the blue LED is illuminated you are not transmitting your AIS data to other vessels, your AIS is acting as a receive-only device. Depress the Silent Mode button a second time transmit your position data.

Both of these functions can be accessed through the Link2AIS™ software when a switch is not installed.

SECTION 4 - MAINTENANCE

WARNING: Unauthorized opening of the Nauticast™-B AIS system will invalidate the warranty.

CAUTION: Avoid using chemical solvents to clean the Nauticast™-B AIS as some solvents can damage the case material. To clean, wipe down with a damp cloth.

NOTE: The Nauticast™-B AIS contains no user serviceable parts. Contact your Service Agent for repair.

APPENDIX A - SERIAL DATA INTERFACE

1.Power/ Data connection

There is a 15-pin D-Sub female connector mounted on the side of the transponder case. The standard data/power cable assembly provided mates with this connector.

NOTE: Both thumb screws on the power/data cable will be tightened securely.

Power

12V DC (9.6-15.6V) is connected to the transponder power supply input via the data/power cable. The red wire is the positive lead and the black wire is the negative lead.

22

Y1-03-0222 Rev. C

Image 22
Contents Page Y1-03-0222 Rev. C Please Read ALL Warnings What is AIS? OverviewAIS classes Installation Product contentsSoftware installation Installation overview and prerequisitesPrerequisites Installation of the .NET Framework Installation of the Windows Installer Installation of the Link2AIS Software Y1-03-0222 Rev. C Y1-03-0222 Rev. C Y1-03-0222 Rev. C Y1-03-0222 Rev. C Connecting to a personal computer PC Help file Installers only Entering static dataSoftware structure Y1-03-0222 Rev. C Hardware installation Electrical connectionsAntenna connections on the transponder Antenna installationPhysical mounting Antenna mountingUsing the Transponder Switching onData port messages LED indicatorsPower Built-in testMaintenance Appendix a Serial Data Interface Power/ Data connectionVHF data link messages Nmea 0183 VDM Power up messagesSerial Port Input/Output DataVDL Message number VDM Message description VDO message format VHF data link own vessel messages Nmea 0183 VDOVDO Message number VDO Message description ACA message format ACS message formatALR message format AIS alarm messages Nmea 0183 ALR, TextACK messages Format DescriptionSpecifications Appendix B Specifications and WarningsParameter Value Appendix C System Block Diagram System DiagramDescription DB15 Appendix D Data Power Cable InformationClass B A2-07-0196-1 ColorUseful Life Policy Limited WarrantySupport Other noticesRepresentative ManufacturerEuropean Signed on behalf of ACR Electronics, Inc