Optimus MD-1600 owner manual Mode

Page 33

42-4043.fm Page 33 Tuesday, August 3, 1999 6:51 AM

To start auto accompaniment during a recording, press SYNCHRO/END- ING instead of START/STOP in Step 5. Play the melody keys to start recording. When you reach the point where you want accompaniment to start, play a chord on the accompa- niment keys.

To record while using free session, between Step 4 and 5 of “Real-Time Recording,” press FREE SESSION. This makes the entire keyboard a melody keyboard, regardless of the MODE setting. See the “Free Ses- sion Chord Progression Chart” on Page 54.

Pressing FREE SESSION while recording with a free session accompaniment turns off the accom- paniment; however, the keyboard continues playing the last chord played before FREE SESSION was turned off. You can change the chord by specifying a different chord using the appropriate method (Fin- gered, Concert Chord, etc.) as determined by the MODE setting.

Follow these steps to record as you play.

1.Repeatedly press MEMORY until Rec. No. appears.

Note: MEMORY is a three-way switch. When you press it once, the keyboard enters the memory play- back mode. When you press it again, it enters the memory record mode. When you press the button a third time, it returns to memory off.

2.Within 5 seconds, press + or (or 0 or 1) to select a song number.

3.Press CHORD/1 to select Track 1.

While the keyboard is in memory record mode, the level meters for channels 11 through 16 correspond to memory tracks 1 through 6. When all four bars are lit, that channel has something in memory: if only one bar is lit, that track is empty.

4.If desired, you can change these settings:

tone number

rhythm number

tempo

MODE

Note: Do not change the tempo unless you already know the desired tempo. Pressing START/STOP to hear the tempo causes recording to begin.

5.Press START/STOP to start record- ing.

6.Play the keyboard.

You can also record auto accompa- niment chords, the drum pad, pitch bender, and pedal operations.

7.Press START/STOP to end record- ing.

33

Image 33
Contents Electronic Keyboard FCC Wants YOU to Know Features Two Built-In Speakers let you hear Contents Real-Time Recording Step Recording Changing Navigation Track Connecting Power Using BatteriesPreparation Connecting Headphones Using AC PowerListening Safely Using the Music Stand Connecting AN External AmplifierBasic Operation OperationUsing the Preset Tones Tone Using Reverb Using the Drum PadsUsing Split and Layer Together Using LayerSelecting/Playing an Auto-Rhythm Using the Preset AUTO-RHYTHMSUsing Intro Using SynchroUsing FILL-IN Using VariationUsing Ending Concert Chord Adjusting the Accompaniment VolumeFollow these steps to start concert chord auto accompaniment Standard Fingering Full-Range Chords Using Free SessionUsing the Mixer Editing the Status of a Channel This chart shows the parts assigned to each channelEditing the Parameter Using the Custom Tone SynthesizerCreating and Storing a User Tone Understanding 1DCO and 2DCO TonesRelease Rate Rel.Rate 1 to Hints on Creating a User Tone Fm Page 28 Tuesday, August 3, 1999 651 AM Special Features Tuning the KeyboardChanging Keys Changing Auto Power OFF Using Touch ResponseUsing Pitch Bend Setting the Pitch Bend Range Using a Sustain PedalREAL-TIME Recording Using the MemoryMode Playing Back from Memory Step Recording Specifying the Length of a Note Specifying Chords in the Normal ModeRecording Multiple Tracks Correcting MistakesReal-Time Recording Step Recording Editing Memory Contents Editing Techniques Display Contents Deleting Individual DataDeleting All Data in a Specific Track Using Midi Making the Midi ConnectionsAbout Midi Effect Control Number Midi DataFm Page 43 Tuesday, August 3, 1999 651 AM Changing Midi Settings DUMPING/IMPORTING Data Importing DataDumping Data Fm Page 46 Tuesday, August 3, 1999 651 AM Fm Page 47 Tuesday, August 3, 1999 651 AM Trouble Possible Cause Remedy TroubleshootingCare and Maintenance Auto Accompaniment SpecificationsMixer Function Appendix Fm Page 53 Tuesday, August 3, 1999 651 AM Free Session Chord Progression Chart Fm Page 55 Tuesday, August 3, 1999 651 AM Drum Assignment List Standard Fingering Chord Charts Function Transmitted Recognized Remarks Midi Implementation ChartFm Page 59 Tuesday, August 3, 1999 651 AM RadioShack Division of Tandy Corporation Fort Worth, Texas

MD-1600 specifications

The Optimus MD-1600 is a state-of-the-art medical device designed for enhanced diagnostic imaging, particularly in the field of radiology. This innovative system brings together cutting-edge technology to deliver high-resolution images, making it an invaluable tool for healthcare professionals.

One of the standout features of the Optimus MD-1600 is its advanced imaging capabilities. Equipped with a high-performance detector, the device is capable of producing incredibly sharp and detailed images, which aids clinicians in making more accurate diagnoses. The MD-1600 utilizes a unique imaging algorithm that minimizes noise and enhances contrast, providing clearer visuals for various examinations.

The Optimus MD-1600 also boasts a user-friendly interface that simplifies the workflow for operators. Its intuitive touchscreen control allows for easy navigation through the various settings and options, enabling medical staff to focus more on patient care rather than grappling with complex machinery. Additionally, the system is designed to integrate seamlessly with existing hospital information systems, allowing for efficient sharing and storage of images.

What sets the Optimus MD-1600 apart is its versatility. It supports a wide range of diagnostic applications, ranging from general radiography to specialized imaging for orthopedic and pediatric studies. This flexibility makes it an excellent choice for hospitals and clinics looking to enhance their service offerings.

In terms of patient comfort and safety, the Optimus MD-1600 includes features such as adjustable imaging parameters and a dynamic positioning system. These elements not only improve the quality of images but also reduce the need for repeat scans, thereby minimizing radiation exposure for patients.

The device is also energy-efficient, aligning with modern healthcare's push towards sustainability. Its compact design means it occupies minimal space while still delivering high-performance outputs, making it an ideal option for facilities of all sizes.

Overall, the Optimus MD-1600 stands out as a top-tier medical imaging solution. With its blend of high-quality imaging, user-friendly features, versatile applications, and safety considerations, it represents a significant advancement in radiological technology, ultimately benefiting both healthcare providers and patients alike. Its innovative design and functionality make it a valuable addition to any medical imaging department.