Optimus MD-1600 owner manual Midi Data, Effect Control Number

Page 42

42-4043.fm Page 42 Tuesday, August 3, 1999 6:51 AM

To send MIDI data from your keyboard, use a MIDI cable to connect the MD- 1600’s MIDI OUT terminal to the other device’s MIDI IN terminal.

To receive MIDI data on your keyboard, use a MIDI cable to connect the MD- 1600’s MIDI IN terminal to the other de- vice’s MIDI OUT terminal.

Note: You do not need to make both connections if you are only either send- ing or receiving.

MIDI DATA

Your MD-1600 can send and receive several different types of MIDI data. The MD-1600’s tones, rhythms, and other types of MIDI data are sent automatical- ly as you play.

Notes:

The MD-1600’s demonstration tunes cannot be sent as MIDI data.

For detailed specifications of the MIDI function, see the “MIDI Imple- mentation Chart” on Page 58.

Note On/Off specifies which keys are pressed (Note On) or released (Note Off). Also includes how loud a note is played as a value from 0 to 127.

Notes:

The pitch of a note depends on the tone that is being used, as shown in the “Note Table” on Page 52.

42

If the keyboard receives a “request” to play notes outside of its range (higher or lower), it automatically selects the same note in the nearest octave.

Program Change specifies the tone.

Pitch Bend supplies pitch bend infor- mation. A Pitch Bend operation on this keyboard changes the pitch of the built- in sound source and sends a Pitch Bend message through the MIDI OUT terminal.

Control Change adds effects such as vibrato and volume changes applied during keyboard play. The message in- cludes a control number (the effect type) and a control value (the on/off and depth of the effect).

Here is the data that can be sent and re- ceived with this keyboard and the corre- sponding control number.

Effect

Control

 

 

Number

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Bank Select

0, 32

 

 

 

 

 

 

 

 

Volume

7

 

 

 

 

 

 

 

 

Pan

10

 

 

 

 

 

 

 

 

Expression

11

 

 

 

 

 

 

 

 

Hold1 (Sustain)

64

 

 

 

 

 

 

 

 

Sostenuto

66

 

 

 

 

 

 

 

 

Soft Pedal

67

 

 

 

 

 

 

 

 

RPN (Registered Parameter

100/101

 

 

 

Number)

 

 

 

 

 

 

 

 

 

Data Entry

6/38

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Image 42
Contents Electronic Keyboard FCC Wants YOU to Know Features Two Built-In Speakers let you hear Contents Real-Time Recording Step Recording Changing Navigation Track Connecting Power Using BatteriesPreparation Connecting Headphones Using AC PowerListening Safely Connecting AN External Amplifier Using the Music StandOperation Basic OperationUsing the Preset Tones Tone Using the Drum Pads Using ReverbUsing Layer Using Split and Layer TogetherUsing the Preset AUTO-RHYTHMS Selecting/Playing an Auto-RhythmUsing Synchro Using IntroUsing FILL-IN Using VariationUsing Ending Adjusting the Accompaniment Volume Concert ChordFollow these steps to start concert chord auto accompaniment Standard Fingering Using Free Session Full-Range ChordsUsing the Mixer This chart shows the parts assigned to each channel Editing the Status of a ChannelUsing the Custom Tone Synthesizer Editing the ParameterUnderstanding 1DCO and 2DCO Tones Creating and Storing a User ToneRelease Rate Rel.Rate 1 to Hints on Creating a User Tone Fm Page 28 Tuesday, August 3, 1999 651 AM Special Features Tuning the KeyboardChanging Keys Changing Auto Power OFF Using Touch ResponseUsing Pitch Bend Using a Sustain Pedal Setting the Pitch Bend RangeUsing the Memory REAL-TIME RecordingMode Playing Back from Memory Step Recording Specifying Chords in the Normal Mode Specifying the Length of a NoteRecording Multiple Tracks Correcting MistakesReal-Time Recording Step Recording Editing Memory Contents Editing Techniques Display Contents Deleting Individual DataDeleting All Data in a Specific Track Using Midi Making the Midi ConnectionsAbout Midi Midi Data Effect Control NumberFm Page 43 Tuesday, August 3, 1999 651 AM Changing Midi Settings DUMPING/IMPORTING Data Importing DataDumping Data Fm Page 46 Tuesday, August 3, 1999 651 AM Fm Page 47 Tuesday, August 3, 1999 651 AM Troubleshooting Trouble Possible Cause RemedyCare and Maintenance Specifications Auto AccompanimentMixer Function Appendix Fm Page 53 Tuesday, August 3, 1999 651 AM Free Session Chord Progression Chart Fm Page 55 Tuesday, August 3, 1999 651 AM Drum Assignment List Standard Fingering Chord Charts Midi Implementation Chart Function Transmitted Recognized RemarksFm Page 59 Tuesday, August 3, 1999 651 AM RadioShack Division of Tandy Corporation Fort Worth, Texas

MD-1600 specifications

The Optimus MD-1600 is a state-of-the-art medical device designed for enhanced diagnostic imaging, particularly in the field of radiology. This innovative system brings together cutting-edge technology to deliver high-resolution images, making it an invaluable tool for healthcare professionals.

One of the standout features of the Optimus MD-1600 is its advanced imaging capabilities. Equipped with a high-performance detector, the device is capable of producing incredibly sharp and detailed images, which aids clinicians in making more accurate diagnoses. The MD-1600 utilizes a unique imaging algorithm that minimizes noise and enhances contrast, providing clearer visuals for various examinations.

The Optimus MD-1600 also boasts a user-friendly interface that simplifies the workflow for operators. Its intuitive touchscreen control allows for easy navigation through the various settings and options, enabling medical staff to focus more on patient care rather than grappling with complex machinery. Additionally, the system is designed to integrate seamlessly with existing hospital information systems, allowing for efficient sharing and storage of images.

What sets the Optimus MD-1600 apart is its versatility. It supports a wide range of diagnostic applications, ranging from general radiography to specialized imaging for orthopedic and pediatric studies. This flexibility makes it an excellent choice for hospitals and clinics looking to enhance their service offerings.

In terms of patient comfort and safety, the Optimus MD-1600 includes features such as adjustable imaging parameters and a dynamic positioning system. These elements not only improve the quality of images but also reduce the need for repeat scans, thereby minimizing radiation exposure for patients.

The device is also energy-efficient, aligning with modern healthcare's push towards sustainability. Its compact design means it occupies minimal space while still delivering high-performance outputs, making it an ideal option for facilities of all sizes.

Overall, the Optimus MD-1600 stands out as a top-tier medical imaging solution. With its blend of high-quality imaging, user-friendly features, versatile applications, and safety considerations, it represents a significant advancement in radiological technology, ultimately benefiting both healthcare providers and patients alike. Its innovative design and functionality make it a valuable addition to any medical imaging department.