to the front panel of the central unit.

AF OUT

BAL/UNBAL

DC IN

LEV 6dBu MAX

12V/150mA

To mount two central units into a rack:

￿Place the two central units side by side upside-down onto a flat surface.

￿ Align the jointing plate

over the holes in the bottom sides of the central

units.

 

￿ Secure the jointing plate

to the central units using eight of the supplied

recessed head screws (M 3x6).

￿ Hook the two rack mount “ears” to the front panels of the central units.

￿Secure the rack mount “ears” to the central units using two of the sup- plied recessed head screws (M 3x6) respectively.

￿Slide the central units into the 19” rack.

￿Secure the rack mount “ears” to the rack.

To mount only one central unit into a rack: ￿ Hook the two rack mount “ears”

￿Secure the rack mount “ears” to the central unit using two of the supplied recessed head screws (M 3x6) respectively.

￿ Secure the blanking plate to one of the rack mount “ears” using two of the supplied recessed head screws (M 6x10).

￿If you are not front mounting the BNC output connector, insert the two

blanking plugs

into the holes of the blanking plate.

￿Slide the central unit into the 19” rack.

￿Secure the rack mount “ears” to the rack.

Connecting the mains unit

￿ Connect the supplied mains unit to the socket (DC IN). Use the cable grip to secure the power supply DC cable.

￿ Connect the suitable adapter to the mains unit .

￿ Connect the mains unit to the mains. The device switches on automatically.

AF OUT

BAL/UNBAL

DC IN

LEV 6dBu MAX

12V/150mA

Connecting the amplifier

The audio outputs are available as a balanced XLR-3M output and an unbalanced BNC output , allowing you to simultaneously connect two devices (amplifier, etc.). Both outputs deliver the same output voltage, are short-circuit proof and decoupled from each other.

￿Connect the amplifier/mixing console to the balanced XLR-3M output

or the unbalanced BNC output .

For details on balanced or unbalanced connection, see “Connector assign- ment” on page 12.

8

Image 10
Contents Overload Page Contents Use of the MO 2000 CU central unit Safety instructionsRack mounting Operation ServiceIntended use of the device MO 2000 Set Delivery includes Product overview MO 2000 Set Overload LEDFitting the device feet Setting up the devicePutting the system into operation Rack mountingConnecting the mains unit Connecting the amplifierAdjusting the sensitivity Connecting the optical microphoneSwitching the central unit on/off Overload indicationTo clean the MO 2000 CU central unit Care and maintenanceAccessories Cat.-No. AccessoryMO 2000 CU central unit SpecificationsMO 2000 H optical microphone Connection fiber optic cable extension optional Connector assignmentFrequency response curve Optical transducer optionalCE Declaration of Conformity WarrantyManufacturer Declarations Statements regarding FCC and industry CanadaPage