Shure SCM800 Remote Volume Control of Channels, Procedure For channel control, For Aux In control

Page 11

REMOTE VOLUME CONTROL OF CHANNELS

The channel, aux, or master levels can be controlled remotely by a dc voltage via an external VCA (Voltage Controlled Ampli- fier). An example of an external VCA is the ST-VCA1 from Ra- dio Design Labs (1–800–281–2683 or www.rdlnet.com).

Procedure:

For channel control:

1.Connect the tip of a 1/4-in. connector to the line input of the VCA, and the sleeve to the ground of the VCA.

2.Connect the ring to the line output of the VCA.

3.Plug the 1/4-in. connector to the Insert jack of the SCM800.

4.Set the channel level control should be set to 5.

For Aux In control:

1.Connect the external source to the VCA line input.

2.Connect the VCA line output to the tip and sleeve of the SCM800 Aux input.

3.Set the Aux control to 5.

For Master control:

1.Connect SCM800 Line output to the VCA line input.

2.Connect the VCA line output to the external device (amplifi- er, tape recorder, etc.).

3.Set Master control to 5.

11

Image 11
Contents 6&0 +7&+$11/0,&523+210,5 Page SCM800 Front Panel FeaturesDescription SCM800 Rear Panel SCM800 120 VAC Power Connector and RockerSCM800E 230 VAC Power Connector and Rocker SCM800/E Connections System SetupOutput Limiter Threshold Settings Rack Mounting the SCM800/EAdditional Link Cables Using AN SCM800 AS a SubmixerLinking Multiple SCM800 Mixers Linking to Other Shure Automatic MixersLow Cut Filter High-Pass Basic Mixer OperationLimiter Equalizer FunctionsSpecifications Modifying the SCM800E for 100-120 VAC, 50/60 HZ Operation Internal ModificationsRemoving the TOP Cover Modifying the SCM800 for 220-240 VAC, 50/60 HZ OperationLocal AUX Operation Disable Master Level ControlLINE-LEVEL Output to MIC-LEVEL Output Change Limiter ThresholdFor Master control Remote Volume Control of ChannelsProcedure For channel control For Aux In control