SPECIFICATIONS
Transducer Type | ||
Frequency Response | 60 to 20,000Hz | |
Polar Pattern | Cardioid | |
Output Impedance | 147 Ω |
|
Sensitivity | −37 dBV/Pa (14.1 mV) | |
(at 1 kHz, open circuit voltage) | 1 Pascal=94 dB SPL | |
Maximum SPL | 1000 | Ω load: 139 dB |
(1 kHz at 1% THD) | 2500 | Ω load: 139 dB |
| THD of microphone preamplifier when applied input signal is equiva- | |
| lent to cartridge output at specified SPL | |
| 86 dB |
|
(referenced at 94 dB SPL at 1 | S/N ratio is difference between 94 dB SPL and equivalent SPL of self | |
kHz) | noise, | |
Dynamic Range | 1000 | Ω load: 131 dB |
(at 1 kHz) | 2500 | Ω load: 131 dB |
Common Mode Rejection | > 60 dB | |
(10 Hz to 100 kHz) |
|
|
Clipping Level | 1000 | Ω load: 6.5 dBV |
2500 | Ω load: 8 dBV | |
Self Noise | 8.5 dB | |
(typical, equivalent SPL, |
|
|
|
| |
Polarity | Positive pressure on diaphragm produces positive voltage on pin 2 | |
| with respect to pin 3 | |
Weight | Net: 494 g | |
| with shock mount and pop filter: 820 g | |
Connector | ||
Power Requirements | 11 to 52 Vdc phantom, 6 mA |
8