Load Impedance
Maximum SPL capability, output clipping level, and dynamic range vary with the in- put load impedance of the preamplifier to which you connect the microphone. Shure recommends a minimum input load impedance of 1000 Ω. Most modern microphone preamplifiers meet this requirement. Higher impedance results in better performance for these specifications.
Power Requirements
This microphone requires phantom power and performs best with a 48 Vdc supply
Most modern mixers provide phantom power. You must use a balanced microphone cable:
SPECIFICATIONS
Cartridge Type | Electret Condenser |
|
Polar Pattern | ||
| ing surface) |
|
Frequency Response | 20 to 20,000 Hz |
|
Output Impedance | 146 Ω |
|
@ 1 kHz |
|
|
Sensitivity | ||
open circuit voltage, @ 1 kHz, typical |
|
|
Maximum SPL | 2500 Ω load | 155 dB |
1 kHz at 1% THD[2] | 1000 Ω load | 151 dB |
64.5 dB |
| |
Dynamic Range | 2500 Ω load | 125.5 dB |
@ 1 kHz | 1000 Ω load | 121.5 dB |
Clipping Level | 2500 Ω load | 12.5 dBV |
20 Hz to 20 kHz, 1% THD | 1000 Ω load | 7.5 dBV |
Self Noise | 29.5 dB |
|
equivalent SPL, |
|
|
Common Mode Rejection | ≥55 dB |
|
20 Hz to 200 kHz |
|
|
Frequency Contour Switch | 7 dB of attenuation centered at 400 kHz | |
Connector | ||
Polarity | Positive pressure on diaphragm produces positive | |
| voltage on pin 2 with respect to pin 3 | |
Power Requirements | ||
Net Weight | 470 g (16.6 oz.) |
|
[1]1 Pa=94 dB SPL
[2]THD of microphone preamplifier when applied input signal level is equivalent to cartridge output at specified SPL
[3]S/N ratio is the difference between 94 dB SPL and equivalent SPL of self noise,
[4]All specifications measured with a 48 Vdc phantom power supply. The microphone operates at lower voltages, but with slightly decreased headroom and sensitivity.
Accessories and Parts
Furnished Accessories
Zippered Carrying Bag | 95A2314 |
Optional Accessories
7.6 m (25 ft.) Cable | C25E |
Replacement Parts
Cardioid Cartridge | RPM98A/C |
CERTIFICATION
Eligible to bear CE Marking. Conforms to European EMC Directive 2004/108/EC. Meets Harmonized Standards
The Declaration of Conformity can be obtained from:
Authorized European representative: Shure Europe GmbH
Headquarters Europe, Middle East & Africa Department: EMEA Approval Wannenacker Str. 28
4