Crown Power Base-2 Minimum Guaranteed Power Watts, Power Base-3 Minimum Guaranteed Power Watts

Page 16

Power Base Series Power Amplifiers

International Units 120 VAC, 60 Hz Units AC Mains

Power Base-2 – Minimum Guaranteed Power (Watts)

 

 

(Ohms)

Maximum Average

FTC Continuous Average

Stereo-Mono

 

0.1% THD+N

0.1% THD+N

0.05% THD+N

0.1% THD + Noise

Mode

 

Load

(See note 1)

(See note 2)

(See note 3)

(See note 4)

 

 

1 kHz

20Hz-20kHz

1 kHz

1 kHz

20Hz-20kHz

 

 

 

 

 

 

 

 

 

 

 

Stereo

4

460

425

460

385

 

(both channels

 

 

 

 

 

 

 

driven)

8

325

310

325

310

265

Bridge-Mono

8

910

830

905

815

 

 

 

 

 

 

 

 

(balanced output)

16

660

615

655

625

530

Parallel-Mono

2

920

 

915

805

 

 

 

 

 

 

 

 

4

655

 

650

630

 

 

 

 

Stereo

4

425

390

425

395

325

(both channels

 

 

 

 

 

 

 

driven)

8

310

290

305

305

275

 

 

 

 

 

 

 

 

Bridge-Mono

8

855

775

850

790

640

 

 

 

 

 

 

 

(balanced output)

16

620

575

615

615

545

 

 

 

850

 

 

 

 

Parallel-Mono

2

 

845

785

 

4

620

 

615

610

 

 

 

 

Fig. 4.2 Power Base-2 Minimum Power Matrix

International Units 120 VAC, 60 Hz Units AC Mains

Power Base-3 – Minimum Guaranteed Power (Watts)

 

 

(Ohms)

Maximum Average

FTC Continuous Average

Stereo-Mono

 

0.1% THD+N

0.1% THD+N

0.05% THD+N

0.1% THD + Noise

Mode

 

Load

(See note 1)

(See note 2)

(See note 3)

(See note 4)

 

 

1 kHz

20Hz-20kHz

1 kHz

1 kHz

20Hz-20kHz

 

 

 

 

 

 

 

 

 

 

 

Stereo

4

760

715

755

 

 

(both channels

 

 

 

 

 

 

 

driven)

8

540

525

540

530

495

Bridge-Mono

8

1525

1430

1500

 

 

 

 

 

 

 

 

 

(balanced output)

16

1090

1045

1075

1055

985

Parallel-Mono

2

1530

 

1520

 

 

 

 

 

 

 

 

 

4

1080

 

1080

1065

 

 

 

 

Stereo

4

680

630

660

555

485

(both channels

 

 

 

 

 

 

 

driven)

8

510

495

505

510

470

 

 

 

 

 

 

 

 

Bridge-Mono

8

1335

1240

1305

1115

1085

 

 

 

 

 

 

 

(balanced output)

16

1025

980

1000

1025

930

 

 

 

1365

 

 

 

 

Parallel-Mono

2

 

1340

1115

 

4

1015

 

1010

1030

 

 

 

 

Fig. 4.3 Power Base-3 Minimum Power Matrix

Page 16

Image 16 Contents
Models Power Base -1, 2 Three Year Full Warranty Crown Audio Division Technical Support Group Magnetic FieldContents Illustrations Page Welcome FeaturesUnpacking Stereo Mode Installation StereoMono Example in .1. Only use the channel 1 inputAdditional Load Protection Input Sensitivity AdjustmentRequired AC Mains Precautions Power IndicatorOperation Protection Systems Filter Cleaning Controls Transformer Thermal Protection Fuses and Circuit BreakersSpecifications PowerPerformance CrosstalkIndicators Output SignalInput/Output ProtectionMinimum Power Specifications Power Base-1 Minimum Guaranteed Power WattsPower Base-2 Minimum Guaranteed Power Watts Power Base-3 Minimum Guaranteed Power WattsMaximum Power Specifications Power Base-1 Maximum Power WattsPower Base-2 Maximum Power Watts Power Base-3 Maximum Power WattsMT-XLR AccessoriesMT-BB Service Worldwide ServiceNorth American Service Crown Audio DivisionCash/Check Visa MasterCard C.O.DCard Number Exp. Date