Pioneer VSX-9120TXH-K manual Operations on the Receiver and Cable Connections

Page 6

Operations on the Receiver and Cable Connections (Continued)

2 From the receiver’s “Manual MCACC” menu, select “EQ Professional” then “Reverb Measurement” to measure the reverb characteristics of your room.

(For details, see page 41 of the receiver’s Operating Instructions.)

Reverberation characteristics can also be measured with “Auto MCACC” but it takes longer than with “Reverb Measurement” because other settings will be made prior to reverb measurement.

Note

Measurement using “Auto MCACC” is only available if you have selected “ALL”, “ALL (Keep SPsetting)” or “Aco Cal EQ Pro.” as the Auto Mode setting.

To see the reverb characteristics of your listening area without the equalization performed by this receiver (before calibration), select “EQ OFF”:

To see the reverb characteristics of your listening area with the equalization performed by this receiver (after calibration), select “ALL” or “ALL (Keep SPsetting)” as the Auto Mode setting in the Auto MCACC setup (see page 33 in the receiver’s operating instructions), then select “EQ ON”:

3 After measurement is complete, select “Reverb Output PC” in the on-screen display.

The message “Start the MCACC application on your PC” appears and the receiver enters transmission standby mode. It is ready to send data to your PC.

This completes the preparations for sending the measurement data to your PC. (To send the data, proceed to the next section Application Operations.)

6

Image 6
Contents VSX-91TXH VSX-9120TXH-K About the Advanced Mcacc Application Requirements for using the application on your PCMain features of the application Things you can accomplish with this applicationInstalling the Application TroubleshootingClick Finish Operations on the Receiver and Cable Connections Connect the receiver to your PC with a RS-232C cableOperations on the Receiver and Cable Connections Application Operations Receiving measurement dataGraph displays names and functions of parts Menu bar and menu icons Date and time File memo Saving graphs in data files To save measure data, choose Save from the File menuOpening data files Exiting the applicationHow to Interpret the Graphs How to interpret reverb graphsDeciding the time period for Advanced EQ Setup calibration Comparison of microphone data acquisition time periodsSee page 34 to 35 in the receiver’s Operating Instructions Checking steps to improve your room’s reverb characteristics Case 4 a specific channel is slow to start Displaying reverb characteristics after calibration Other Functions Receivable measurement dataReceiving and saving measurement data Opening measurement data files Updating and Deleting the Application Updating the applicationClick OK Click Finish Deleting the application Click Yes Troubleshooting TELContinue Cause ALL display mode graphs cannot be printed Cause Pioneer Corporation