Heatiator Rave4013i-c Connecting the DV-46DVA-GCL Adapter to Appliance Top Vent, Floor Hearth

Page 34

Connecting the DV-46DVA-GCL Adapter to Appliance Top Vent

Remove top seal cap and insulation if equipped. See Section 14, “Appliance Setup.” Attach the DV-46DVA- GCL adapter to the appliance starting collar with 3-1/2 in. self-tapping screws. See Figure 7.16.

Connecting the LINK-DV30B to the DV-46DVA-GCL adapter

Insert the two sections of flexible vent pipe down the existing chimney.

Attach one section of flexible vent pipe to the exhaust collar on top of the DV-46DVA-GCL adapter with three self-tapping screws.

Attach one section of flexible vent pipe to the inlet collar on top of the DV-46DVA-GCL adapter with three self- tapping screws.

To minimize cold air drafts, seal around the flex vents at the damper inside the chimney with non-combustible unfaced fiberglass or rock wool insulation.

The DV-46DVA-GCL adapter must be recessed into existing masonry fireplace. This measurement is taken from the top of the fireplace opening. See Table 1 and Figure 7.15.

WARNING! Risk of Fire, Explosion or Asphyxiation! Do NOT connect this gas appliance to a chimney flue serving a separate solid fuel or gas burning appliance.

May impair safe operation of this appliance or other appliances connected to the flue.

Vent this appliance directly outside.

Use separate vent system for this appliance.

CAUTION! DO NOT use any flue restric- tor when venting with the DV-46DVA-GCL adapter and LINK-DV30B kit. This may re- sult in poor flame appearance, sooting, pilot malfunction, or overheating.

NOTICE: To achieve optimum per- formance of appliance, minimize or avoid bends in exhaust vent pipe.

EXISTING CHIMNEY

EXHAUST AIR

VENT PIPE

EXISTING CHIMNEY

 

V

 

DIRECT VENT FIREPLACE

Minimum

10 ft.

3.05 m

 

Maximum

40 ft.

12.2 m

 

 

 

 

 

FLOOR

HEARTH

 

TOP VENT

TERMINATION CAP

V

INLET AIR

VENT PIPE

To minimize cold air

drafts, seal with

non-combustible insulation.

Figure 7.16

34

Heatilator • RAVE4013I-C2293-900 Rev. C • 8/12

Image 34
Contents What to do if you smell gas HOT SurfacesCongratulations Homeowner Reference InformationTable of Contents User GuideFinishing Appliance SetupTroubleshooting Reference MaterialsLimited Lifetime Warranty Limited Lifetime WarrantyWarranty Conditions Listing and Code Approvals Installation of Carbon Monoxide Detectors Requirements for the Commonwealth of MassachusettsOperating Instructions User Guide Gas Fireplace SafetyYour Fireplace Clear Space Fixed Glass AssemblyRemote Controls, Wall Controls and Wall Switches Decorative Doors and FrontsWhat to do if YOU Smell GAS Lighting Instructions IPIFinal inspection by GAS ValveIssue Solutions Frequently Asked QuestionsInitial Break-in Procedure After Fireplace is LitMaintenance and Service Firebox Maintenance Tasks-Qualified Service TechnicianGasket Seal and Glass Assembly Inspection Control Compartment and Firebox TopGetting Started Typical Appliance SystemTools and Supplies Needed Design and Installation ConsiderationsInspect Appliance and Components Framing and Clearances Selecting Appliance LocationConstructing the Appliance Chase Minimum Framing Dimensions ClearancesSheathing 12 Mantel and Wall ProjectionsCombustible Mantels Non-combustible Mantels Thick Wall SheathingNon-Combustible Zone Termination Locations Vent Termination Minimum ClearancesCovered Alcove Applications Minimum Clearances for TerminationVent Information and Diagrams Top Vent Horizontal Termination Venting with 1 elbow Minimum H1 MaximumTop Vent Horizontal Termination Venting with 2 elbows H1 + H2 MaximumTop Vent Horizontal Termination RAVE4013I-CTop Vent Horizontal Termination Venting with 3 elbows Top Vent Vertical Termination No Elbows V1 = 44 ft. Max .4 m Exhaust restrictor InstructionsTop Vent Vertical Termination Venting with 2 elbows V1 Minimum Maximum V1 + V2 MinimumTop Vent Vertical Termination Venting with 3 elbows Top Vent Vertical Termination Venting with 4 elbows V1 MIN H1 MAX V2 MIN H2 MAX V3 MINClearances to Combustibles Prior to installing the gas applianceCoaxial to Colinear Venting Termination Cap Flue DamperFloor Hearth Connecting the DV-46DVA-GCL Adapter to Appliance Top VentConnecting the LINK-DV30B to the DV-46DVA-GCL adapter Termination CAP Inlet AIR Vent PipeWall Penetration Framing Vent Clearances and FramingPipe Clearances to Combustibles Combustible Wall PenetrationInstall the Ceiling Firestop Pipe SLPFlat Ceiling Installation Install Attic Insulation ShieldVaulted Ceiling Installation Appliance Preparation Top VentSecuring and Leveling the Appliance Proper Positioning, Leveling And SecuringInstalling Vent Pipe SLP Pipe Assemble Vent SectionsAssemble Slip Sections Secure The Vent SectionsInstall Decorative Ceiling Components Disassemble Vent SectionsInstall Metal Roof Flashing Assemble and Install Storm CollarInstall Decorative Wall Components Install Vertical Termination CapHeat Shield Requirements for Horizontal Termination Install Horizontal Termination Cap 17 Venting through the wallFuel Conversion Access Through the Valve AssemblyGas Information Gas PressureGas Connection Disconnect Gas ValveOptional Accessories Requirements Wiring RequirementsIntelliFire Ignition System Wiring Electrical InformationElectrical Service and Repair Junction Box Installation Finishing Instructions FinishingFraming and Finishing Instructions Non-Combustible Materials SpecificationFACTORY-INS Talled Painting Finish and Sealing JointsFinishing Around Opening with Gypsum Wallboard Wallboard Joint-Crack Prevention and RepairMinimum Facing Material 2 IN. Above Standoff10 Inside Fit Method Deco Decorative Front Only Decorative Fronts Illusion Decorative FrontClean the Appliance Appliance SetupRemove Fixed Glass Assembly AccessoriesAir Shutter Setting Install the MeshAir Shutter Settings Symptom Possible Cause Corrective Action TroubleshootingIntelliFire Ignition System To remove any contaminants that may have accumulated Appliance Dimension Diagram Reference MaterialsSLP-HVS Vent Components DiagramsSLP-FS SLP-WS318 mm 305 mm12-1/2 205 mm15-1/2 394 mm 178 mm 305 mm SLP-HRC-SS SLP-HRC-ZC-SS Horizontal Termination CAPSLP-LPC Optional Wire HarnessPVI-SLP LINK-DV30B DVP-2SL DV-46DVA-GCLDRC-RADIUS At Depot Service PartsService Parts List Landscape Gas Fireplace DV#12 Valve Assembly TUP-GBK-12 Contact Information

Rave4013i-c specifications

The Heatiator Rave4013i-c stands out as an exceptional heating solution designed to provide efficient, reliable warmth while elevating the aesthetic appeal of any space. This advanced model offers a blend of innovative technology, high performance, and user-friendly features.

One of the most notable characteristics of the Rave4013i-c is its cutting-edge air distribution system. This ensures uniform heat distribution throughout the room, eliminating cold spots and providing consistent warmth. The unit's powerful heat output makes it suitable for various environments, including residential homes, offices, and commercial spaces.

The Rave4013i-c is equipped with energy-efficient technologies that reduce power consumption while maintaining optimal performance. With an impressive heating capacity, the unit is designed to heat larger spaces effectively without incurring steep energy costs. Users appreciate its eco-friendly design, which aligns with today's sustainability goals, helping to lower carbon footprints.

Another significant feature is the sophisticated digital control panel, which allows users to customize their heating experience. The intuitive interface provides easy access to various settings, including temperature adjustments, timer functions, and mode selection. This level of control ensures that users can achieve their desired comfort level with minimal hassle.

The Heatiator Rave4013i-c also boasts an aesthetically pleasing design, incorporating sleek lines and a modern finish that complements any decor. The charming appearance does not compromise its robustness; it is built from high-quality materials that promise durability and long-lasting performance.

Safety is a top priority for the Rave4013i-c. It includes essential safety features such as overheat protection and tip-over switches. These integrated safety measures provide peace of mind, especially in homes with pets and small children. Additionally, its low noise operation allows for peaceful enjoyment of the warmth generated, without disruptive sounds.

Versatility is another hallmark of the Rave4013i-c. It can be installed in various configurations, whether flush-mounted in a wall or standing independently, making it adaptable to different room layouts. This flexibility, combined with its heating efficiency and modern design, makes the Heatiator Rave4013i-c an ideal choice for anyone seeking a high-quality heating appliance that enhances both comfort and style.