C. Facing Material

Facing and/or finishing materials must not interfere with air flow through louvers, operation of louvers or doors, or access for service.

Facing and/or finishing materials must never overhang into the glass opening.

Observe all clearances when applying combustible materials.

WARNING! Risk of Fire! DO NOT apply combustible materials beyond the minimum clearances. Comply with all minimum clearances to combustibles as specified in this manual. Overlapping materials could ignite and will interfere with proper operation of doors and louvers.

WARNING! Risk of Fire! DO NOT install drywall or other combustible materials over the factory-installednon-com- bustible board. Overlapping materials could ignite.

Decorative facing material thickness is measured from the face of the factory-installed non-combustible board. See Figure 13.8.

Non-Combustible Finish Materials

0 - 1 inch Thickness-Overlap Fit Method

Both the Deco and Illusion decorative fronts are designed to overlap finish materials 0 inches to 1 inch thick. See Figure 13.8.

NOTICE: This one inch maximum not only includes the decorative finish materials (marble, tile, slate, etc) but also the thinset, and adhesive used to attach the decorative finish material.

The non-combustible finish material can be installed up to the fireplace opening covering the top, left and right finishing flanges. See Figure 13.8.

Requirements for finishing to bottom of fireplace opening are specific to decorative fronts as follows:

DECO: Non-combustible finish materials maybe installed up to the fireplace opening, covering lower finishing flange.

ILLUSION: Requires a minimum of 1 inch clearance to the non-combustible finishing material from the bottom fireplace opening. See Figure 13.9.

1-1/2 IN. ABOVE STANDOFF

FACTORY-INSTALLED

 

NON-COMBUSTIBLE BOARD

NON-COMBUSTIBLE

FINISHING MATERIAL

0 - 1 IN. THICK

DECO DECORATIVE

FRONT SHOWN

BOTTOM

SIDE PLATE

STOP

1 IN. MIN.

ILLUSION

FRONT

RETURN BEND

LOWER

COVER PANEL

NON-COMBUSTIBLE

FINISHING MATERIAL

0 - 1 IN. THICK

DRYWALL OR

EQUIVALENT (1/2 IN.)

Figure 13.8 Overlap Fit Method (Deco or Illusion Decorative Front)

Both the Deco and Illusion decorative fronts can be in- stalled with an “Overlap” or “Inside Fit” method:

Overlap Requirement: See Figure 13.8 and 13.9

Inside Fit requirement: See Figure 13.10.

1/2 IN. BUILDING MATERIAL

OPTIONAL FINISH MATERIAL

Figure 13.9. Illusion Front, Side View - Bottom Side Plate Installed Over Lower Cover Panel

Reference dimensions for the Deco and Illusion fronts installed on the appliance are shown in Figure 13.14 and Figure 13.15.

54

Heatilator • RAVE4013I-C2293-900 Rev. C • 8/12

Image 54
Contents What to do if you smell gas HOT SurfacesCongratulations Homeowner Reference InformationTable of Contents User GuideFinishing Appliance SetupTroubleshooting Reference MaterialsLimited Lifetime Warranty Limited Lifetime WarrantyWarranty Conditions Listing and Code Approvals Installation of Carbon Monoxide Detectors Requirements for the Commonwealth of MassachusettsGas Fireplace Safety Operating Instructions User GuideYour Fireplace Clear Space Fixed Glass AssemblyRemote Controls, Wall Controls and Wall Switches Decorative Doors and FrontsWhat to do if YOU Smell GAS Lighting Instructions IPIFinal inspection by GAS ValveIssue Solutions Frequently Asked QuestionsInitial Break-in Procedure After Fireplace is LitMaintenance and Service Firebox Maintenance Tasks-Qualified Service TechnicianGasket Seal and Glass Assembly Inspection Control Compartment and Firebox TopGetting Started Typical Appliance SystemDesign and Installation Considerations Tools and Supplies NeededInspect Appliance and Components Framing and Clearances Selecting Appliance LocationConstructing the Appliance Chase Minimum Framing Dimensions ClearancesSheathing 12 Mantel and Wall ProjectionsCombustible Mantels Non-combustible Mantels Thick Wall SheathingNon-Combustible Zone Termination Locations Vent Termination Minimum ClearancesCovered Alcove Applications Minimum Clearances for TerminationVent Information and Diagrams Top Vent Horizontal Termination Venting with 1 elbow Minimum H1 MaximumTop Vent Horizontal Termination Venting with 2 elbows H1 + H2 MaximumTop Vent Horizontal Termination RAVE4013I-CTop Vent Horizontal Termination Venting with 3 elbows Top Vent Vertical Termination No Elbows V1 = 44 ft. Max .4 m Exhaust restrictor InstructionsTop Vent Vertical Termination Venting with 2 elbows V1 Minimum Maximum V1 + V2 MinimumTop Vent Vertical Termination Venting with 3 elbows Top Vent Vertical Termination Venting with 4 elbows V1 MIN H1 MAX V2 MIN H2 MAX V3 MINClearances to Combustibles Prior to installing the gas applianceCoaxial to Colinear Venting Termination Cap Flue DamperFloor Hearth Connecting the DV-46DVA-GCL Adapter to Appliance Top VentConnecting the LINK-DV30B to the DV-46DVA-GCL adapter Termination CAP Inlet AIR Vent PipeWall Penetration Framing Vent Clearances and FramingPipe Clearances to Combustibles Combustible Wall PenetrationInstall the Ceiling Firestop Pipe SLPInstall Attic Insulation Shield Flat Ceiling InstallationVaulted Ceiling Installation Appliance Preparation Top VentSecuring and Leveling the Appliance Proper Positioning, Leveling And SecuringInstalling Vent Pipe SLP Pipe Assemble Vent SectionsAssemble Slip Sections Secure The Vent SectionsInstall Decorative Ceiling Components Disassemble Vent SectionsInstall Metal Roof Flashing Assemble and Install Storm CollarInstall Vertical Termination Cap Install Decorative Wall ComponentsHeat Shield Requirements for Horizontal Termination Install Horizontal Termination Cap 17 Venting through the wallFuel Conversion Access Through the Valve AssemblyGas Information Gas PressureGas Connection Disconnect Gas ValveOptional Accessories Requirements Wiring RequirementsIntelliFire Ignition System Wiring Electrical InformationElectrical Service and Repair Junction Box Installation Finishing Instructions FinishingFraming and Finishing Instructions Non-Combustible Materials SpecificationFACTORY-INS Talled Painting Finish and Sealing JointsFinishing Around Opening with Gypsum Wallboard Wallboard Joint-Crack Prevention and RepairMinimum Facing Material 2 IN. Above Standoff10 Inside Fit Method Deco Decorative Front Only Decorative Fronts Illusion Decorative FrontClean the Appliance Appliance SetupRemove Fixed Glass Assembly AccessoriesInstall the Mesh Air Shutter SettingAir Shutter Settings Troubleshooting Symptom Possible Cause Corrective ActionIntelliFire Ignition System To remove any contaminants that may have accumulated Appliance Dimension Diagram Reference MaterialsSLP-HVS Vent Components DiagramsSLP-FS SLP-WS318 mm 305 mm12-1/2 205 mm15-1/2 394 mm 178 mm 305 mm SLP-HRC-SS SLP-HRC-ZC-SS Horizontal Termination CAPSLP-LPC Optional Wire HarnessPVI-SLP LINK-DV30B DVP-2SL DV-46DVA-GCLDRC-RADIUS At Depot Service PartsService Parts List Landscape Gas Fireplace DV#12 Valve Assembly TUP-GBK-12 Contact Information

Rave4013i-c specifications

The Heatiator Rave4013i-c stands out as an exceptional heating solution designed to provide efficient, reliable warmth while elevating the aesthetic appeal of any space. This advanced model offers a blend of innovative technology, high performance, and user-friendly features.

One of the most notable characteristics of the Rave4013i-c is its cutting-edge air distribution system. This ensures uniform heat distribution throughout the room, eliminating cold spots and providing consistent warmth. The unit's powerful heat output makes it suitable for various environments, including residential homes, offices, and commercial spaces.

The Rave4013i-c is equipped with energy-efficient technologies that reduce power consumption while maintaining optimal performance. With an impressive heating capacity, the unit is designed to heat larger spaces effectively without incurring steep energy costs. Users appreciate its eco-friendly design, which aligns with today's sustainability goals, helping to lower carbon footprints.

Another significant feature is the sophisticated digital control panel, which allows users to customize their heating experience. The intuitive interface provides easy access to various settings, including temperature adjustments, timer functions, and mode selection. This level of control ensures that users can achieve their desired comfort level with minimal hassle.

The Heatiator Rave4013i-c also boasts an aesthetically pleasing design, incorporating sleek lines and a modern finish that complements any decor. The charming appearance does not compromise its robustness; it is built from high-quality materials that promise durability and long-lasting performance.

Safety is a top priority for the Rave4013i-c. It includes essential safety features such as overheat protection and tip-over switches. These integrated safety measures provide peace of mind, especially in homes with pets and small children. Additionally, its low noise operation allows for peaceful enjoyment of the warmth generated, without disruptive sounds.

Versatility is another hallmark of the Rave4013i-c. It can be installed in various configurations, whether flush-mounted in a wall or standing independently, making it adaptable to different room layouts. This flexibility, combined with its heating efficiency and modern design, makes the Heatiator Rave4013i-c an ideal choice for anyone seeking a high-quality heating appliance that enhances both comfort and style.