PX3
How to change the Value Dial and +/- Functions
∙#1- Hold down the Exit button and press the left edit button, the Value Dial will now adjust the Master Level of all programs. The +/- button will select programs.
∙#2- Hold down the Exit button and press the right edit button, the Value Dial will now adjust the Programs. The +/- buttons will adjust the master level.
∙#3- Hold down the Exit button and press the Bypass/Tune button, this turns on the KEYLOCK Function. The +/- buttons will select the Programs, all other buttons and the Value Dial will not function. Since you can only select programs in the Keylock mode, it prevents unintended changes to the PX3 settings in live performance.
∙To exit this function, hold down the Exit button and press the button for the desired setting.
Edit Mode
∙Press the right edit button. The Drive Icon will blink. Keep pressing the right Edit button to go through all the different Effect banks in order.
∙Press the Bypass/Tune button to turn the Effects ON/OFF.
∙+/- Button selects the Effect Type, High Gain & Low Gain, Cabinet size, and Character locations.
∙The Value Dial adjusts Parameter value, Gain effect level, Cabinet Depth, Noise reduction depth, Master program level, Characters, Key for Intelligent Pitch shifter, and writing destination for user programs.
7