Reference Manual D AD 3220 B Version 1.0
Switch Function Detail
All settings are stored in Flash Ram inside the module (see Auto Store section in this manual). Settings will be recalled on power up.
Dip Switch 1
This switch enables local control using the dip- switches. ON enables local control and makes selections on the dipswitch active, and OFF disables local control (locking out any local changes)
Note.
When Switch 1 is initially switched to ON, the static settings currently set on the
Dip Switch 2
This switch selects the mode of operation for the module. ON selects dual 1 into 4 mode where each individual AES input is distributed to four outputs. OFF selects 1 into 8 mode where input AES in 1 is distributed to all 8 outputs.
Dip Switch 3
This is not used
Dip Switch 4
This is not used
Page 16